Purpose This study compared the outcomes of minimally invasive plate osteosynthesis and antegrade intramedullary nailing for low-energy fracture of the distal femoral shaft. Materials and Methods A study was conducted on 30 patients who underwent surgery for low-energy fractures of the distal femoral shaft between January 2016 and April 2022. The study compared 15patients who underwent minimally invasive plate osteosynthesis (Group P) with 15 patients who underwent recon-type antegrade intramedullary nailing (Group N). We evaluated intraoperative blood loss, operative time, C-arm exposure time, bone density, final union status, anatomical reduction, and clinical evaluation. The complications were also examined, and statistical analysis was conducted to compare the two groups. Results The blood loss, surgery time, and C-arm time were similar in the two groups. The radiographic assessments and clinical evaluations were also similar in the two groups. The clinical results showed no difference between the groups. Group N had one case of nonunion and one case of delayed union, while Group P had one case of nonunion and one case of peri-prosthetic fracture. Conclusion Antegrade intramedullary nailing of the recon-type demonstrated comparable results to minimally invasive plate osteosynthesis. Hence, antegrade intramedullary nailing of the recon-type, which enhances stability by fixing the entire femur and providing additional fixation in the distal portion, is deemed appropriate for treating distal femoral shaft fractures.
Purpose This study examined the difference in bone union time according to the fracture gap after minimally invasive plate osteosynthesis (MIPO) for simple distal femoral fractures in elderly patients. Materials and Methods From January 2010 to December 2019, patients aged 60 years or older who underwent surgical treatment for distal femoral fractures due to a low-energy injury were investigated retrospectively. Forty patients were enrolled in the study. The patients were divided into two groups according to the fracture gap after reduction: no more than 2 mm (Group A) and more than 2 mm (Group B) in the anteroposterior and lateral plane. The demographic, operation time, presence or absence of cerclage wiring, plate screw density, plate span ratio, plate length, bone union period, non-union, and complications were evaluated. Results No statistical differences in operation time, cerclage wiring, plate screw density, plate span ratio, and plate length were observed between the two groups, and the bone union was achieved in all patients without complication. The bone union period was 17.24±1.48 weeks in Group A and 24.53± 5.20 weeks in Group B, which was statistically significant (p<0.001). Conclusion The bone union time in treating geriatric simple distal femur fractures using the MIPO tech-nique was significantly shorter in the 2 mm or less fracture gap than in the greater than 2 mm group.
Purpose This study compared minimally invasive plate osteosynthesis (MIPO) using a single small skin incision and conventional open volar locking plate fixation (OP) for distal radius fracture to identify outcome difference. Materials and Methods Forty-three patients who underwent MIPO using a single small skin incision or OP for distal radius fractures were evaluated retrospectively. Of the patients, 21 were treated with MIPO using a single small skin incision and 22 with the OP method through the conventional volar approach. The postoperative radiographic results and clinical outcomes at the final follow-up in each group were compared. Results All patients achieved bone union in the MIPO and OP groups. No significant differences in the bone union time, alignment, range of motion, QuickDASH, or pain score were observed. On the other hand, the size of the incision was significant: 23 mm in the MIPO group and 55 mm in the OP group (p<0.001). Conclusion MIPO technique using a single small incision showed similar satisfactory radiographic and functional outcomes compared to conventional OP for distal radius fractures. The MIPO technique using a single small incision offered advantages, including cosmetic benefits and minimal soft tissue damage, is recommended, particularly in young women and high functional demand patients.
PURPOSE Many international journals have published studies on the results of distal femoral fractures in elderly people, but only a few studies have been conducted on the Korean population. The aim of this study was to determine the factors that are associated with the outcomes and prognosis of fixation of distal femur fractures using the minimally invasive plate osteosynthesis (MIPO) technique in elderly patients (age≥60) and to determine the risk factors related witht he occurrence of nonunion. MATERIALS AND METHODS This study is a retrospective study. From January 2008 to June 2018, distal femur fracture (AO/OTA 33) patients who underwent surgical treatment (MIPO) were analyzed. A total of 52 patients were included in the study after removing 121 patients that met with the exclusion criteria. Medical records, including surgical records, were reviewed to evaluate the patients' underlying disease, bone mineral density, the number of days delayed from surgery, complications and mortality. In addition, follow-up radiographs were used to determine bone union, delayed union and nonunion. RESULTS The average time to achieve bone union was 19.95 weeks, the rate of nonunion was 20.0% (10/50) and the overall mortality was 3.8% (2/52). There were no significant differences in the clinical and radiological results of those patients with or without periprosthetic fracture. On the univariate analysis, which compared the union group vs. the nonunion group, no factors were identified as significant risk factors for nonunion. On the multiple logistic regression analysis, medical history of cancer was identified as a significant risk factor for nonunion (p=0.045). CONCLUSION The rate of nonunion is high in the Korean population of elderly people suffering from distal femur fracture, but the mortality rate appears to be low. A medical history of cancer is a significant risk factor for nonunion. Further prospective studies are required to determine other associated factors.
Citations
Citations to this article as recorded by
Comparison of Clinical Outcomes for Femoral Neck System and Cannulated Compression Screws in the Treatment of Femoral Neck Fracture Jae Kwang Hwang, KiWon Lee, Dong-Kyo Seo, Joo-Yul Bae, Myeong-Geun Song, Hansuk Choi Journal of the Korean Fracture Society.2023; 36(3): 77. CrossRef
PURPOSE This study compared the radiological and clinical results of minimally invasive plate osteosynthesis (MIPO) and intramedullary nailing (IMN) of distal tibial fractures, which were classified as the simple intra-articular group and extra-articular group. MATERIALS AND METHODS Fifty patients with distal tibial fractures, who could be followed-up more than 12 months, were evaluated. Group A consisted of 19 patients treated with MIPO and group B consisted of 31 patients treated with IMN. The results of each group were analyzed by radiological and clinical assessments. RESULTS The mean operation times in groups A and B were 72.4 minutes and 65.7 minutes, respectively. The mean bone union times in groups A and B were 16.4 weeks and 15.7 weeks, respectively. The bone union rate in groups A and B were 100% and 93%, respectively. The ranges of ankle motion were similar in the two groups at the last follow-up. The mean American Orthopaedic Foot and Ankle Society score was similar: 90.1 in group A and 90.5 in group B. The radiological and clinical results were similar in the intra and extra-articular groups. In groups A and B, two cases of posterior angulation and five cases of valgus deformity of more than 5° were encountered. CONCLUSION Both MIPO and IMN achieved satisfactory results in extra-articular AO type A and simple articular extension type C1 and C2 distal tibia fractures.
Citations
Citations to this article as recorded by
Intramedullary Nailing versus Minimally Invasive Plate Osteosynthesis for Distal Tibia Shaft Fractures: Retrospective Comparison of Functional and Cosmetic Outcomes Kahyun Kim, In Hee Kim, Geon Jung Kim, SungJoon Lim, Ji Young Yoon, Jong Won Kim, Yong Min Kim Journal of Korean Foot and Ankle Society.2023; 27(3): 93. CrossRef
PURPOSE To analyze the clinical and radiologic results of minimally invasive plate osteosynthesis (MIPO) for distal femur fractures using a locking compression plate (LCP) and to evaluate its usefulness. MATERIALS AND METHODS From May 2006 to April 2011, 23 patients (24 cases) with distal femur fracture were treated by MIPO with a LCP and followed-up for at least 12 months. Mean age was 61.6 years (35-80 years). Union time and post-operative alignment were measured on radiograph, and clinical function was evaluated by range of motion (ROM), Knee Society Score and complications. RESULTS In 22 patients (23 cases) except for 1 case, bony union was obtained after an average of 18 weeks (12-26 weeks). The mean ROM was 124 degrees (80-135 degrees). According to the Knee Society Score, there were 12 excellent, 8 good, 1 fair and 2 poor results and the mean score was 87.5 (60-98). Postoperative complications were nonunion in 1 case, ankylosis in 1 case, malunion in 2 cases and superficial wound infection in 2 cases. CONCLUSION The treatment of distal femoral fracture with MIPO using a LCP was considered a useful method which can result in satisfactory clinical and radiologic outcomes if there is accurate understanding about the surgical techniques and appropriate procedures involved.
Citations
Citations to this article as recorded by
Surgical Treatment of AO/OTA 33-C Intra-Articular Distal Femoral Fractures through Parapatellar Approach Suk Kyu Choo, Sung Tan Cho, Hyoung Keun Oh Journal of the Korean Fracture Society.2022; 35(1): 1. CrossRef
Incidence of nonunion after surgery of distal femoral fractures using contemporary fixation device: a meta‐analysis Byung-Ho Yoon, In Keun Park, Youngwoo Kim, Hyoung-Keun Oh, Suk Kyu Choo, Yerl-Bo Sung Archives of Orthopaedic and Trauma Surgery.2021; 141(2): 225. CrossRef
PURPOSE To investigate the surgical outcomes of patients with femoral mid-diaphyseal fractures treated with minimally invasive plate osteosynthesis (MIPO), which were difficult to intramedullary nailing. MATERIALS AND METHODS We evaluated 11 patients with femoral mid-diaphyseal fractures who were treated with MIPO. There were 7 males and 4 females and the mean age was 47 years (20-85 years). According to AO/OTA classification, there were 1 type of A1, 5 types of A3, 1 of B2 and 4 of B3. The reason of plate fixation instead of intramedullary nailing is as follows: femoral vessel and severe soft tissue injuries-2 cases, polytrauma patients with chest injury-6 cases, and narrow medullary canal diameter-3 cases. Six out of 11 cases were treated with initial external fixation as a damage control orthopedics. RESULTS The mean union time of 6 cases was 3.7 months (3-5 months). There were 5 cases (45%) of nonunion, which should be treated with autogenous bone graft. All cases of nonunion resulted from severe soft tissue damage and polytrauma, which needed initial external fixation. There was no case of malalignment and implant-related complication. CONCLUSION In cases of difficult intramedullary nailing for the femoral mid-diaphyseal fractures, MIPO could be an alternative surgical option, but concurrent soft tissue injuries and multiple trauma may increase the risk of nonunion in spite of biological fixation.
PURPOSE To evaluate the clinical and radiological results of minimally invasive plate, osteosynthesis, using either a locking compression plate-distal tibia (LCP-DT) or Zimmer periarticular locking plate (ZPLP) for distal tibia fractures. MATERIALS AND METHODS Fifty one patients (51 cases), who underwent minimally invasive osteosynthesis using locking compression plate for distal tibia fractures between October 2008 and August 2011, were followed for more than six months. Eighteen patients were treated with LCP-DT and 33 patients with ZPLP. Time to bony union and anatomic alignment were evaluated radiologically. Clinically, American Orthopedic Foot & Ankle Society ankle-hindfoot scales (AOFAS score) and range of ankle motion were assessed and compared between two groups. RESULTS All patients achieved bony union at an average of 18 weeks on LCP-DT group and 16weeks on ZPLP group. The average American Orthopedic Foot & Ankle Society ankle-hindfoot scales was 83.3 points on the LCP-DT group, 84.6 points on the ZPLP group, and range of ankle motion averaged at 45 degrees, 48 degrees, respectively. CONCLUSION Both types of locking compression plates were effective when performing minimally invasive osteosynthesis for distal tibia fractures.
Citations
Citations to this article as recorded by
Biomechanical analysis and clinical effects of bridge combined fixation system for femoral fractures Da-xing Wang, Ying Xiong, Hong Deng, Fu Jia, Shao Gu, Bai-lian Liu, Qun-hui Li, Qi Pu, Zhong-zi Zhang Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine.2014; 228(9): 899. CrossRef
PURPOSE Our study aimed to investigate the clinical and radiological results of humerus proximal or distal shaft fractures treated with minimally invasive plate osteosynthesis (MIPO) using a 3.5/5.0 metaphyseal locking plate. MATERIALS AND METHODS We reviewed the clinical and radiographic records of 17 patients with humeral proximal or distal shaft fractures who had undergone 3.5/5.0 metaphyseal locking plate osteosynthesis with a minimally invasive technique. We evaluated the results with respect to the anatomical reduction and union of the humerus shaft fracture through radiologic studies. We also evaluated the clinical results using the motion of shoulder and elbow functional outcome, American Shoulder and Elbow Surgeons (ASES) score, Mayo elbow performance score (MEPS), and postoperative complications. RESULTS Complete union was achieved in all cases. The mean union time was 14.2 weeks. According to the functional outcome rated by the ASES score and MEPS, 15 cases were considered excellent and 2 cases were good. There were no cases of surgically-related complications like metal failure, loss of anatomical reduction, or postoperative nerve injuries. CONCLUSION Using a 5.0 metaphyseal locking plate for humerus shaft fracture has the limitation that difficulties can arise in achieving sufficient screw fixation for small bony fragments. The 3.5/5.0 metaphyseal locking plate used in MIPO for humerus 1/3 proximal or distal shaft fractures was concluded to give good clinical and radiologic results.
Citations
Citations to this article as recorded by
Polarus Intramedullary Nail for Proximal Humeral and Humeral Shaft Fractures in Elderly Patients with Osteoporosis Youn-Soo Hwang, Kwang-Yeol Kim, Hyung-Chun Kim, Su-Han Ahn, Dong-Eun Lee Journal of the Korean Fracture Society.2013; 26(1): 14. CrossRef
PURPOSE To compare results of minimally invasive plate osteosynthesis using a locking compression plate and a periarticular locking plate in distal femur fractures. MATERIALS AND METHODS We retrospectively reviewed 31 consecutive femoral fractures who treated by minimally invasive plate osteosynthesis from April 2006 to May 2009. Sixteen patients were treated using a locking compression plate (group A) and 15 patients were treated using a periarticular locking plate (group B). RESULTS The mean operation time was 78 minutes and 76 minutes (p=0.273), and the mean radiation exposure time was 1.9 minutes and 2.3 minutes (p=0.001) in the group A and B, respectively. The plate bending during operation was performed in 4 cases of group A. The knee range of motion was 117.5degrees and 118.2degrees (p=0.825), and the Lysholm score was 81.3 and 81.8 (p=0.723) in the group A and B, respectively. Schazker criteria showed more than good grade in 93.8% of group A and in 93.3% of group B (p=1.0). CONCLUSION No significant differences in clinical results were observed between the two groups. However, a lower anatomical compliance was showed in the locking compression plate, and a higher risk of radiation exposure was showed in the periarticular locking plate.
Citations
Citations to this article as recorded by
Incidence of nonunion after surgery of distal femoral fractures using contemporary fixation device: a meta‐analysis Byung-Ho Yoon, In Keun Park, Youngwoo Kim, Hyoung-Keun Oh, Suk Kyu Choo, Yerl-Bo Sung Archives of Orthopaedic and Trauma Surgery.2021; 141(2): 225. CrossRef
The Mid-Term Result after Osteosynthesis of Intra-Articular Fractures of Distal Femur Sam Guk Park, Jeong Jae Moon, Oog Jin Shon Journal of the Korean Fracture Society.2016; 29(4): 242. CrossRef
PURPOSE To compare results between minimally invasive plate osteosynthesis using a periarticular plate and intramedullary nailing in distal tibial metaphyseal fractures in two treatment groups. MATERIALS AND METHODS Sixty-one cases of distal tibial metaphyseal fractures from December 2008 to December 2009 were evaluated. The minimal follow-up period was 12 months. Thirty patients treated by minimally invasive plate osteosynthesis using a periarticular plate were Group A; 31 patients treated by intramedullary nailing were Group B. We compared and analyzed the results of each group by radiological and clinical assessments. RESULTS The mean bony union time was 16.4 weeks in Group A and 17.2 weeks in Group B. The mean operation time was 45 minutes in Group A and 48 minutes in Group B. The mean radiation exposure times were 4.2 minutes and 4.8 minutes, respectively. VAS scores were 0.7 points and 0.5 points in each respective group. In Group A, the VAS score was 1.7 points when we applied pressure on the skin around the plate. The mean Olerud and Molander Ankle Score was 87.4 points and 86.3 points, respectively. A superficial wound infection occurred in 1 case in each group, and angular deformities more than 5 degrees occurred in 2 Group B cases. CONCLUSION No significant differences in results were observed between the two groups. However, a higher incidence of angular deformity was seen in the intramedullary nailing group. Therefore, we must be careful during surgery.
Citations
Citations to this article as recorded by
Comparative Analysis of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Distal Tibia Fractures Ho-Min Lee, Young-Sung Kim, Jong-Pil Kim, Phil-Hyun Chung, Suk Kang, Kaung Suk Jo Journal of the Korean Fracture Society.2018; 31(3): 94. CrossRef
A Comparison of the Results between Intramedullary Nailing and Minimally Invasive Plate Osteosynthesis in Distal Tibia Fractures Chul-Hyun Park, Chi-Bum Choi, Bum-Jin Shim, Dong-Chul Lee, Oog-Jin Shon Journal of the Korean Orthopaedic Association.2014; 49(4): 285. CrossRef
PURPOSE To analyze the result of distal femur fracture treatment with minimally invasive plate osteosynthesis (MIPO) using a locking compression plate (LCP). MATERIALS AND METHODS From December 2004 to April 2010, 33 patients with distal femur fractures were treated by MIPO with a locking compression plate. The reduction state and bone union time was checked radiologically. The clinical outcome was evaluated by the Schatzker and Lambert criteria. RESULTS The mean bone union time was 16.3 weeks (10~22 weeks). There were 3 nonunions, 2 broken plates, 1 superficial infection, 7degrees of valgus angulation in 1 case, and 1.5 cm limb shortening in 1 case. Except for the 3 nonunion cases, according to the Schatzker and Lambert criteria, results were graded as excellent in 11 cases, good in 14 cases, and moderate in 5 cases. CONCLUSION The treatment of distal femoral fracture by MIPO with a locking compression plate resulted in good functional and radiological outcomes, but it has problems, such as broken plates and nonunion. Accurate surgical technique and appropriate treatment will be needed according to fracture type.
Citations
Citations to this article as recorded by
Surgical Treatment of AO/OTA 33-C Intra-Articular Distal Femoral Fractures through Parapatellar Approach Suk Kyu Choo, Sung Tan Cho, Hyoung Keun Oh Journal of the Korean Fracture Society.2022; 35(1): 1. CrossRef
Comparing Outcomes of Retrograde Intramedullary Nail and Locking Plate Fixation in Distal Femoral Fractures Byung-Ho Yoon, Bo Kwon Hwang, Hyoung-Keun Oh, Suk Kyu Choo, Jong Min Sohn, Yerl-Bo Sung Journal of the Korean Fracture Society.2021; 34(4): 131. CrossRef
Incidence of nonunion after surgery of distal femoral fractures using contemporary fixation device: a meta‐analysis Byung-Ho Yoon, In Keun Park, Youngwoo Kim, Hyoung-Keun Oh, Suk Kyu Choo, Yerl-Bo Sung Archives of Orthopaedic and Trauma Surgery.2021; 141(2): 225. CrossRef
Minimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Femur Fracture Sung Won Cho, Sang Ho Ha, Gwang Chul Lee, Woong Hee Kim Journal of the Korean Fracture Society.2013; 26(3): 205. CrossRef
The minimally invasive plate osteosynthesis (MIPO) which is extensively performed, is very dependent on the indirect reduction technique to prevent the exposure of fracture sites. Indirect reduction with the use of the femoral distractor is a much more efficient technique to restore the length in the fracture of lower limbs. However, the femoral distractor cannot be used for fracture of upper limbs, and other instruments for indirect reduction have not yet been reported. Therefore, we introduce the novel indirect reduction technique with the use of the lumbar spreader for the MIPO of upper limbs.
PURPOSE To compare the result of treatment between minimally invasive plate osteosynthesis (MIPO) using periarticular plate and intramedullary nailing in treatment of distal tibia fractures. MATERIALS AND METHODS 28 cases of distal tibia fractures form Jan. 2006 to Mar. 2008 were divided into two group. Minimum follow-up was for 12 month. Group 1 consisted of 14 patients who were treated by MIPO technique and group 2 consisted of 14 patients who were treated by interlocking intramedullary nailing. The results were compared by assessing radiologic and clinical result. RESULTS The mean bony union time was 14 weeks (8~17) in group 1 and 15 weeks (11~20) in group 2. Operation time was 58 minutes (55~65) in group 1 and 82.7 minutes (70~100) in group 2. The average angulation in AP view was 1.5 degrees (0~2) in group 1 and 2 degrees (0~5) in group 2, in lateral view was 1.8 degrees (0~4) in group 1 and 2.3 degrees (0~12) in group 2. The average range of motion for dorsi flextion was 17.5 degrees (15~20) in group 1 and 18 degrees (16~20) in group 2, for plantar flextion was 45 degrees (42~50) in group 1 and 44 degrees (42~50) in group 2, which means that there were no severe limitation of motion in all patients, resulting in satisfactory ambulation. There was no post operative complications such as skin irritation problem caused by internal device and no implant failure and superficial wound infection. CONCLUSION There were no difference in bony union time, clinical result and anatomical reduction between Group 1 and Group 2 in distal tibia fractures, but operation time was shorter in MIPO than nailing.
PURPOSE To assess the result of staged minimally invasive plate osteosynthesis (MIPO) for distal tibial fracture with an open wound or injured soft tissue. MATERIALS AND METHODS In 20 patients (mean age, 47.8 year-old) with distal tibial fractures, there were 4 type A fractures and 16 type C fractures based on the AO classification system. Eight of the 20 patients had open fractures. MIPO was performed on average 23.9 days after bridging external fixation. At the final follow-up, we assessed the radiological results of bone union and alignment. Functional results were also evaluated by measuring the degrees of ankle motion and the American Orthopedic Foot & Ankle Society (AOFAS) scores. RESULTS Seventeen of 20 cases (85%) achieved primary union at an average of 21.3 weeks. There were 3 cases of nonunion requiring a bone graft. The mean AOFAS score was 88.5 (range, 67~92) and the average range of ankle motion was 49.2degrees (plantarflexion: 37.4degrees, dorsiflexion: 11.8degrees). Complication included 2 cases of minor mal-alignment, 1 case of claw toe and 1 case of peroneal neuropathy. Patients over the age of 60 had lower functional results. Additional factors did not affect the final results. CONCLUSION Staged MIPO may achieve satisfactory results in distal tibial fractures with soft tissue compromise, decreasing deep infections and soft tissue complications.
Citations
Citations to this article as recorded by
Anterolateral Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Using an Anterolateral Locking Plate Dongwhan Suh, Hwan Hee Lee, Young Hoon Han, Jae Jung Jeong Journal of Korean Foot and Ankle Society.2020; 24(1): 19. CrossRef
Minimally Invasive Osteosynthesis with Locking Compression Plate for Distal Tibia Fractures Sung-Kyu Kim, Keun-Bae Lee, Keun-Young Lim, Eun-Sun Moon Journal of the Korean Fracture Society.2011; 24(1): 33. CrossRef
PURPOSE To compare the efficacy of the surgical treatment through the comparison of Minimally Invasive Plate Osteosynthesis (MIPO) and Intramedullary (IM) nailing in the treatment of the tibial shaft fractures expended to metaphysis retrospectively. MATERIALS AND METHODS Patients with proximal or distal third fracture of tibial shaft from May 2003 to Aug. 2006 were divided into two groups depending on the surgical method. Group A consisted of 30 patients treated with IM nailing, Group B was 29 patients treated with MIPO. The clinical outcomes were evaluated retrospectively from the time for bone union and callus formation confirmed by X-ray, functional score of knee or ankle joint, and complications including nonunion, malalignment and infection. RESULTS Bone union was seen radiologically at a mean of 17.4 weeks in group A, and 17.0 weeks in group B. In postoperative complications, group A showed two nonunion, two delayed-union, six malalignment, and two wound infection while group B showed only one delayed-union and one wound infection. CONCLUSION There were no significant differences in the time for bony union and functional score between IM nailing and MIPO. Conventional IM nailing with only interlocking technique showed higher incidence of malalignment and deformity than MIPO for the treatment of the proximal or distal third fracture of the tibial shaft.
Citations
Citations to this article as recorded by
Effect of Korean Medicine Treatments in Patients with Proximal Tibia Fracture: A Retrospective Observational Study Jung Min Lee, Eun-Jung Lee Journal of Korean Medicine Rehabilitation.2020; 30(3): 141. CrossRef
PURPOSE To assess the results of staged MIPO (Minimally Invasive Plate Osteosynthesis) for proximal tibial fractures with compromised soft tissue. MATERIALS AND METHODS Eighteen proximal tibial fractures (AO 41:9 cases, AO 42:9 cases) included this study. Ten were open fractures. After temporary external fixation until soft tissue healed (mean 27.3 days), MIPO was performed secondarily without bone graft. We assessed the bony union and knee function, and affecting factors of the results were investigated. RESULTS All fractures united at 20 weeks (range, 11~32) except 1 case. Mean range of knee flexion was 134.4degrees and mean IOWA knee score was 89.1. There were 2 superficial and 2 delayed deep infections from open fractures (grade II:1 case, grade III:3 cases), although they healed after implant removal. Open fractures seem to influence the infection rate. Otherwise, there was no related factor affecting the results. CONCLUSION MIPO after temporary external fixation can provide favorable results in proximal tibial fractures with soft tissue injuries, but attention of delayed infection should be paid in open fractures.
Citations
Citations to this article as recorded by
MINIMALLY INVASIVE OSTEOSYNTHESIS WITH PLATE OR NAIL FOR META-DIAPHYSEAL TIBIAL FRACTURES - WHAT IS BETTER? B. Makelov Trakia Journal of Sciences.2023; 21(4): 357. CrossRef
Effect of Korean Medicine Treatments in Patients with Proximal Tibia Fracture: A Retrospective Observational Study Jung Min Lee, Eun-Jung Lee Journal of Korean Medicine Rehabilitation.2020; 30(3): 141. CrossRef
Comparison of Time to Operation and Efficacies of Ultrasound-Guided Nerve Block and General Anesthesia in Emergency External Fixation of Lower Leg Fractures (AO 42, 43, 44) Chan Kang, Sang-Bum Kim, Youn-Moo Heo, You-Gun Won, Byung-Hak Oh, June-Bum Jun, Gi-Soo Lee The Journal of Foot and Ankle Surgery.2017; 56(5): 1019. CrossRef
Minimally Invasive Plate Osteosynthesis for Proximal Tibial Shaft Fracture Young-Soo Byun, Ki-Chul Park, Hyun-Jong Bong, Chang-Hoon Lee Journal of the Korean Fracture Society.2011; 24(1): 23. CrossRef
The Use of Fresh Frozen Allogenic Bone Graft in the Impacted Tibial Plateau Fractures Yeung Jin Kim, Soo Uk Chae, Jung Hwan Yang, Ji Wan Lee, Dae Han Wi, Duk Hwa Choi Journal of the Korean Fracture Society.2010; 23(1): 26. CrossRef
Management of Open Fracture Gu-Hee Jung Journal of the Korean Fracture Society.2010; 23(2): 236. CrossRef
Staged Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Sung-Ki Park, Chang-Wug Oh, Jong-Keon Oh, Kyung-Hoon Kim, Woo-Kie Min, Byung-Chul Park, Won-Ju Jeong, Joo-Chul Ihn Journal of the Korean Fracture Society.2010; 23(3): 289. CrossRef
Intramedullary Nailing of Proximal Tibial Fractures Young-Soo Byun, Dong-Ju Shin Journal of the Korean Fracture Society.2009; 22(3): 197. CrossRef
Proximal Tibia Fracture: Plating Ki-Chul Park Journal of the Korean Fracture Society.2009; 22(3): 206. CrossRef
PURPOSE To compare the effectiveness between minimally invasive plate osteosynthesis (MIPO) and interlocking IM nailing in the treatment of distal tibia fracture without involvement of ankle joint retrospectively. MATERIALS AND METHODS 38 patients with distal tibia fracture from Jan. 2004 to Oct. 2005 were divided into two groups. Minimum follow-up was for 12 months. Group MIPO consisted of 18 patients were treated with MIPO and group Nail consisted of 20 patients were treated with interlocking intramedullary nail. The results were compared between two groups by assessing bony union time and operation time. Clinical evaluation was evaluated by Olerud score. RESULTS The mean bony union time was 14.4 weeks (12~17 weeks) in group MIPO and 16.7 weeks (13~19 weeks) in group Nail (p=0.011). The mean operation time was 1.05 hours (0.6~1.6 hours) in group MIPO and 0.74 hours (0.4~1.1 hours) in group Nail (p=0.044). The Olerud score was 83.8 (75~100) in group MIPO and was 89.6 (70~100) in group Nail (p=0.075). In Complication, group MIPO showed one metal failure and two skin irritations, group Nail showed three superficial wound infections. CONCLUSION MIPO was the shorter bony union time and the longer operation time than the interlocking intramedullary nailing. There were no significant differences between the two groups in clinical results.
Citations
Citations to this article as recorded by
Comparative Analysis of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Distal Tibia Fractures Ho-Min Lee, Young-Sung Kim, Jong-Pil Kim, Phil-Hyun Chung, Suk Kang, Kaung Suk Jo Journal of the Korean Fracture Society.2018; 31(3): 94. CrossRef
A Rehabilitation for Ankle Fracture in Korean Medicine: A Report of 4 Cases Won-Bae Ha, Jong-Ha Lee, Yoon-Seung Lee, Dong-Chan Jo, Jin-Hyun Lee, Jung-Han Lee Journal of Korean Medicine Rehabilitation.2017; 27(4): 171. CrossRef
Comparison of the Results between Intramedullary Nailing and Plate Fixation for Distal Tibia Fractures Jung-Han Kim, Heui-Chul Gwak, Chang-Rack Lee, Yang-Hwan Jung Journal of Korean Foot and Ankle Society.2015; 19(3): 86. CrossRef
Intramedullary Nailing of Distal Tibial Fractures with Percutaneous Reduction by Pointed Reduction Forceps Jae-Kwang Hwang, Chung-Hwan Kim, Young-Joon Choi, Gi-Won Lee, Hyun-Il Lee, Tae-Kyung Kim Journal of the Korean Fracture Society.2014; 27(2): 144. CrossRef
A Comparison of the Results between Intramedullary Nailing and Minimally Invasive Plate Osteosynthesis in Distal Tibia Fractures Chul-Hyun Park, Chi-Bum Choi, Bum-Jin Shim, Dong-Chul Lee, Oog-Jin Shon Journal of the Korean Orthopaedic Association.2014; 49(4): 285. CrossRef
Analysis of the Result Treated with Locking Compression Plate-Distal Tibia and Zimmer Periarticular Locking Plate in Distal Tibia Fracture Jun-Young Lee, Sang-Ho Ha, Sung-Won Cho, Sung-Hae Park Journal of the Korean Fracture Society.2013; 26(2): 118. CrossRef
PURPOSE To evaluate the efficiency of lateral plate fixation using minimally invasive plate osteosynthesis (MIPO) technique as a treatment of distal tibial metaphyseal fracture. MATERIALS AND METHODS Among the patient who were treated from March, 2002 to September, 2004, the cases of twenty patients with distal tibial metaphyseal fracture treated by lateral plate fixation using MIPO technique who were able to be followed up for at least one-year period were reviewed in this study. According to AO/OTA classification, five were type A1, twelve cases were type A2 and other three cases were type A3, and among them two cases were open fracture type I according to the Gustillo-Anderson classification. Radiologic studies and clinical assessment described by Daniel et al and complication following the treatment were evaluated. RESULTS At a mean of 16.4 weeks (range 11 to 23), all fractures united without secondary procedures. According to clinical assessment, all cases had good and excellent result, and there were no complications. CONCLUSION The lateral plate fixation using MIPO technique of distal tibial metaphyseal fracture is an efficient method of treatment with high functional recovery rate which minimize soft tissue damage, decreases the risk of infection and incidence of nonunion at the same time as the classic MIPO technique does, and it is a useful alternative method when there is a anteromedial soft tissue damage.
Citations
Citations to this article as recorded by
Minimally Invasive Plate Osteosynthesis for Fractures of Distal Tibia Tae Hun Kim, So Hak Chung Kosin Medical Journal.2014; 29(1): 23. CrossRef
Staged Protocol in Treatment of Open Distal Tibia Fracture: Using Lateral MIPO Oog Jin Sohn, Dong Hwa Kang Clinics in Orthopedic Surgery.2011; 3(1): 69. CrossRef
Minimally Invasive Percutaneous Plate Osteosynthesis Using a Lateral Plate in Distal Tibial Fracture Oog Jin Shon, Dae Sung Kim Journal of the Korean Fracture Society.2010; 23(1): 42. CrossRef
PURPOSE To evaluate the clinical and radiologic results of minimally invasive plate osteosynthesis, We analyzed the cases of distal femoral fracture treated with this newly developed surgical technique. MATERIALS AND METHODS We reviewed 12 cases of distal femoral fracture which had been treated with minimally invasive plate osteosynthesis and each patients had been followed up for a minimum twelve months. Post-operative function was evaluated with checking the range of motion of knee joint and Knee Society Score. Union period and post-operative alignment was measured on radiograph. RESULTS In all cases, bony union was obtained in average fifteen weeks after operation without bone graft. The arc of motion of knee joint which was checked at the last follow up was 123.75 degrees on average. According to Knee Society Score, there were 9 excellent, 1 fair and 1 poor results. The post-operative complications were malunion in 1 case, soft tissue infection in 1 case and joint stiffness in 1 case. CONCLUSION The treatment of distal femoral fracture with minimally invasive plate osteosynthesis is one of the good surgical options for clinically preferable results with high union rate without bone graft and early joint motion.
Citations
Citations to this article as recorded by
Surgical Treatment of AO/OTA 33-C Intra-Articular Distal Femoral Fractures through Parapatellar Approach Suk Kyu Choo, Sung Tan Cho, Hyoung Keun Oh Journal of the Korean Fracture Society.2022; 35(1): 1. CrossRef
Minimally Invasive Plate Osteosynthesis for Femoral Mid-Diaphyseal Fractures Hyoung-Keun Oh, Suk-Kyoo Choo, Jong-In Kim, Sung-Jong Woo Journal of the Korean Fracture Society.2013; 26(2): 140. CrossRef
Minimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Femur Fracture Sung Won Cho, Sang Ho Ha, Gwang Chul Lee, Woong Hee Kim Journal of the Korean Fracture Society.2013; 26(3): 205. CrossRef
Treatment of Distal Femur Fracture with Minimally Invasive Locking Compression Plate Osteosynthesis Ki-Chul Park, Kyu-Sung Chung, Joon-Ki Moon Journal of the Korean Fracture Society.2012; 25(1): 13. CrossRef
PURPOSE To evaluate the efficacy and complication of minimally invasive plate osteosynthesis (MIPO) technique for lateral malleolar fracture. MATERIALS AND METHODS From January 2001 to December 2003, we had treated 13 cases of lateral malleolar fracture (AO-OTA classification, type A: 4, type B: 9) by MIPO technique and followed them up more than 1 year. Operation time, union time, radiologic alignment, range of motion of the ankle joint, functional results according to criteria of Meyer and complication were evaluated. RESULTS After the final follow-up, all the fractures were healed without any second procedure, full-weight bearing ambulation was started in average 10 weeks. Any malunion was not observed by the inadequate bending of plate. Two patients felt a discomfort of ankle because the location of plate was lower than the tip of the lateral malleolus, but all the patients had excellent or satisfactory ankle functions. No deep infection or soft tissue compromise were observed at the last follow up. CONCLUSION Minimally invasive plate osteosynthesis technique is safe and worthwhile method in management of lateral malleous fractures while avoiding the complications associated with conventional open plating methods.
Citations
Citations to this article as recorded by
Percutaneous Plating of Weber B Fibular Fractures Amol Saxena, Andrew Yun The Journal of Foot and Ankle Surgery.2017; 56(2): 366. CrossRef
Minimally invasive percutaneous plate osteosynthesis for ankle fractures: a prospective observational cohort study Robinson Esteves Santos Pires, Cyril Mauffrey, Marco Antônio Percope de Andrade, Leonardo Brandão Figueiredo, Vincenzo Giordano, João Carlos Belloti, Fernando Baldy dos Reis European Journal of Orthopaedic Surgery & Traumatology.2014; 24(7): 1297. CrossRef
PURPOSE evaluate the effectiveness of minimally invasive plate osteosynthesis (MIPO) in unstable fractures of the distal tibia. MATERIALS AND METHODS From March 2001 to December 2003, 21 cases with unstable fractures of the distal tibia were treated with MIPO technique and followed for at least one year. Eighteen cases were extra-articular and three cases were intra-articular fractures. According to AO classification, six cases were 42-A, four 42-B, one 42-C, seven 43-A, and three 43-C. There was only one case of Gustilo-Anderson type II open fracture. We reviewed the results of fracture healing, axial and rotational deformity, ankle motion, and complications RESULTS: All fractures were healed in an average of 16.1 weeks (range, 11 to 24 weeks). There was only one case of 7-degree posterior angular deformity, but no cases of rotational malalignment. Recovery of ankle motion was satisfactory in all patients within 5-degree loss of motion. Subcutaneous abscess was developed in one case after fracture healing and cured by a drainage with implant removal. CONCLUSION Although MIPO technique is technically more demanding than the traditional open technique, MIPO technique is an effective method for unstable fractures of the distal tibia because it minimizes incidence of soft-tissue compromise and infection and provides good fracture healing.
Citations
Citations to this article as recorded by
Clinical Outcomes of Locking Compression Plate Fixation through Minimally Invasive Percutaneous Plate Osteosynthesis in the Treatment of Distal Tibia Fracture Jae-Sung Yoo, Hyun-Woo Park Journal of the Korean Fracture Society.2012; 25(2): 117. CrossRef
Staged Protocol in Treatment of Open Distal Tibia Fracture: Using Lateral MIPO Oog Jin Sohn, Dong Hwa Kang Clinics in Orthopedic Surgery.2011; 3(1): 69. CrossRef
Staged Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Sung-Ki Park, Chang-Wug Oh, Jong-Keon Oh, Kyung-Hoon Kim, Woo-Kie Min, Byung-Chul Park, Won-Ju Jeong, Joo-Chul Ihn Journal of the Korean Fracture Society.2010; 23(3): 289. CrossRef
Management of Fractures of Distal Tibia by Minimally Invasive Plate Osteosynthesis through an Anterior Approach Gu-Hee Jung, Jae-Do Kim, Jae-Ho Jang, Sung-Keun Heo, Dong-won Lee Journal of the Korean Orthopaedic Association.2010; 45(6): 473. CrossRef
Comparative Study Using of Treatment with Minimally Invasive Plate Osteosynthesis Using Periarticular Plate and Interlocking Intramedullary Nailing in Distal Tibia Fractures Chang Hwa Hong, Jong Seok Park, Sang Seon Lee, Soo Ik Awe, Woo Jong Kim, Ki Jin Jung Journal of the Korean Fracture Society.2010; 23(3): 296. CrossRef
A Comparison between Minimally Invasive Plate Osteosynthesis & Interlocking Intramedullary Nailing in Distal Tibia Fractures Kee-Byung Lee, Si-Young Song, Duek-Joo Kwon, Yong-Beom Lee, Nam-Kyou Rhee, Jun-Ha Choi Journal of the Korean Fracture Society.2008; 21(4): 286. CrossRef
Basic Principle of the Locking Compression Plate Keun Bae Lee Journal of the Korean Fracture Society.2008; 21(3): 261. CrossRef
Treatment of High-energy Distal Tibia Intraarticular Fractures with Two-staged Delayed Minimal Invasive Plate Osteosynthesis Hong-Moon Sohn, Jun-Young Lee, Sang-Ho Ha, Jae-Won You, Sang-Hong Lee, Kwang-Chul Lee Journal of the Korean Fracture Society.2007; 20(1): 19. CrossRef
Minimally Invasive Plate Osteosynthesis, MIPO Young-Soo Byun Journal of the Korean Fracture Society.2007; 20(1): 99. CrossRef
Minimally Invasive Percutaneous Plate Osteosynthesis Using Periarticular Plate for Distal Tibial Fractures Young Mo Kim, Jae Hoon Yang, Dong Kyu Kim Journal of the Korean Fracture Society.2007; 20(4): 315. CrossRef