Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Search

Page Path
HOME > Search
30 "Tension band wiring"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Articles
Clinical Outcomes of Triple Tension Band Wirings in Comminuted Patellar Fracture: A Comparison with Conventional Tension Band Wiring
Hyun-Cheol Oh, Han-Kook Yoon, Joong-Won Ha, Sang Hoon Park, Sungwoo Lee
J Korean Fract Soc 2024;37(2):82-86.   Published online April 30, 2024
DOI: https://doi.org/10.12671/jkfs.2024.37.2.82
AbstractAbstract PDF
Purpose
This study devised triple tension band wirings (TTBW) fixation in patients with comminuted patella fractures to compare the clinical result of TTBW with that of tension band wiring (TBW).
Materials and Methods
This study was conducted on 91 patients who had undergone surgery diagnosed with acute patella fracture from January 2011 to December 2016. The study included 51 double TBW patients (Group 1) and 40 patients with TTBW (Group 2).
Results
Five out of 51 cases had a loss of reduction and fixation failure in Group 1, and no failure of fracture formation healing occurred in Group 2. Nonunion was noted in one case in Group 1 and no case in Group 2. Eight K-wire migration cases were observed in Group 1, which was not observed in Group 2. Six patients in Group 1 underwent revisional surgery. No patients in Group 2 had a reoperation. As a result of a one-year follow-up after the operation, the mean range of motion of the knee joint in groups 1 and 2 was 128.3°±11.3° and 127.9°±10.8°, respectively. The Lysholm’s scores for groups 1 and 2 were 90.8±4.2 and 90.3±3.8 points, respectively, which was not statistically significant.
Conclusion
TTBW is a helpful technique for the surgical treatment of comminuted patella fractures. The TTBW method has less reoperation due to nonunion and fixation failure. After a one-year followup, the clinical results were similar to the conventional TBW method.
  • 69 View
  • 0 Download
Close layer
Usefulness of Percutaneous Cannulated Screws with Tension Band Wiring for Minimally Displaced Fractures of the Patella
Ho Min Lee, Jong Pil Kim, Phil Hyun Chung, Eun Woo Bae
J Korean Fract Soc 2022;35(4):142-150.   Published online October 31, 2022
DOI: https://doi.org/10.12671/jkfs.2022.35.4.142
AbstractAbstract PDF
Purpose
To evaluate the usefulness of percutaneous cannulated screws with tension band wiring (PC-STBW), a minimally invasive surgical technique, compared to conservative treatment for a minimally displaced patella transverse fracture.
Materials and Methods
The subjects included patients from 2010 to 2019 with transverse patella fractures, who were diagnosed as minimally displaced fractures, and were followed up for at least 1 year. Of these, 61 patients who were treated with cylinder casts were classified as Group A, and 53 patients who were treated with PCSTBW were classified as Group B. The clinical evaluation was carried out by evaluation of the radiographic bone union and calculation of the Bostman knee score. Any complications observed were investigated.
Results
All patients in both groups showed no further displacement of the fracture gap, and the bone union was achieved in all cases. The functional evaluation of the knee joint measured at the 8- and 12-week follow-up showed superior results in Group B wherein subjects were treated with surgery, and similar results were seen in both groups during the 6 months and 1-year follow-up. One case in Group A suffered the complication of knee stiffness.
Conclusion
For the treatment of minimally displaced transverse patellar fractures, both conservative treatment and PCSTBW showed similar good results at the 6-month and one-year follow-up. However, the PCSTBW technique showed superior clinical results in the early stage follow-up within 12 weeks.
  • 61 View
  • 0 Download
Close layer
Is It Essential to Apply Tension Band Wire Fixation in Non-Comminuted Displaced Transverse Fractures of the Olecranon (Mayo Type 2A)?
In-Tae Hong, Cheungsoo Ha, Seongmin Jo, Wooyeol Ahn, Soo-Hong Han
J Korean Fract Soc 2022;35(3):97-102.   Published online July 31, 2022
DOI: https://doi.org/10.12671/jkfs.2022.35.3.97
AbstractAbstract PDF
Purpose
Various problems have been reported with tension-band wire (TBW) fixation. With the devel-opment of anatomical plates and the improvement of fixation forces, plate fixation is currently being performed for non-comminuted, displaced, transverse olecranon fractures (Mayo Type 2A). This study compared the usefulness of the above two procedures applied in non-comminuted, displaced, transverse olecranon fractures.
Materials and Methods
Fifty-three patients with Mayo Type 2A were studied retrospectively. Twenty-nine patients underwent TBW fixation, while the other 24 underwent plate fixation. The averageoutpatient follow-up period was 10 months for both groups. Both groups were analyzed radiologically and clinically. The radiological assessment included the time to bone union, joint stability, and presence of traumatic osteoarthritis at the final follow-up. The clinical assessment included the operation time,range of motion of the elbow joint, Mayo Elbow Performance Score (MEPS), Disability of the Arm, Shoulder and Hand (DASH) score, and the presence of postoperative complications.
Results
Both groups showed stable elbow joints, proper union of fractures, and no traumatic osteo-arthritis at the final follow-up. The range of motion for the TBW fixation group was 142° (range, 3°-145°), while that of the plate fixation group was 135° (range, 4°-139°) at the final follow-up (p=0.219). The MEPS was 98.2 and 97.7 for the TBW fixation and plate fixation groups, respectively (p=0.675). The DASH score was 10.7 and 13.9 for the TBW fixation and plate fixation groups, respectively. Both groups showed excellent results, and the differences were not statistically significant (p=0.289).
Conclusion
TBW fixation and plate fixation were compared in non-comminuted, displaced, transverse olecranon fractures, and good results were obtained without significant differences between the two groups. Hence, surgeons should choose a technique they are more confident with and can be applied more efficiently.
  • 54 View
  • 1 Download
Close layer
Case Report
Tension Band Wiring Technique for Distal Radius Fracture with a Volar Articular Marginal Fragment: Technical Note
Neunghan Jeon, Jong Keon Oh, Jae Woo Cho, Youngwoo Kim
J Korean Fract Soc 2020;33(1):38-42.   Published online January 31, 2020
DOI: https://doi.org/10.12671/jkfs.2020.33.1.38
AbstractAbstract PDF
Most distal radius fractures are currently being treated with anterior plating using anatomical precontoured locking compression plates via the anterior approach. However, it is difficult to fix the volar articular marginal fragment because these anatomical plates should be placed proximally to the watershed line. There were just a few methods of fixation for this fragment on medical literature. Herein, we introduced a tension band wiring technique for fixation of a volar articular marginal fragment in the distal radius.
  • 131 View
  • 0 Download
Close layer
Original Articles
Treatment of Isolated Lateral Malleolar Fractures Using Locking Compression Plate Fixation and Tension Band Wiring Fixation
Woojin Shin, Seondo Kim, Jiyeon Park
J Korean Fract Soc 2020;33(1):16-21.   Published online January 31, 2020
DOI: https://doi.org/10.12671/jkfs.2020.33.1.16
AbstractAbstract PDF
PURPOSE
The purpose of this study was to compare the clinical and radiological outcomes of locking compression plate (LCP)-screw fixation and tension band wiring (TBW) fixation in isolated lateral malleolar fractures.
MATERIALS AND METHODS
From May 2016 to August 2018, 52 patients with isolated lateral malleolar fracture were retrospectively reviewed. They were divided into 30 cases of the LCP fixation group (Group I) and 22 cases of the TBW fixation group (Group II). The clinical and radiological results of those groups were compared. Pearson chi-square tests and independent t-tests were used in the statistical analysis.
RESULTS
The mean length of the surgical incision was 8.3 cm in Group I and 4.9 cm in Group II. Radiological union was obtained at a mean of 8.4 weeks in both groups. The mean American Orthopaedic Foot and Ankle Society score was 90 (range, 85–97) and 92 (range, 85–100) in Groups I and II, respectively, at the last follow up.
CONCLUSION
Both the LCP-screw and TBW techniques revealed excellent results in isolated lateral malleolar fractures. The tension band technique may be a fine alternative method of fixation in the treatment of isolated lateral malleolar fracture.
  • 143 View
  • 5 Download
Close layer
Usefulness of the Additional K-Wire Fixation and Suture for Reinforce the Treatment of Distal Clavicle Fracture Using Modified Tension Band Wiring
Seung Bum Chae, Chang Hyuk Choi, Dong Young Kim
J Korean Fract Soc 2016;29(2):107-113.   Published online April 30, 2016
DOI: https://doi.org/10.12671/jkfs.2016.29.2.107
AbstractAbstract PDF
PURPOSE
We attempted to evaluate the clinical results of modified tension band wiring (MTBW) with additional K-wire fixation and suture for distal clavicle fracture.
MATERIALS AND METHODS
Fifty-nine patients with a distal clavicle fracture from May 2009 to December 2013 treated with MTBW were enrolled in this study. Their fracture types were type 2, 12; and type 3, 33; type 4, 8; and type 5, 6 according to Craig classification group II; average age was 47.2 years with a mean follow-up period of 27.9 months. The operations were performed within a mean of 3.1 days a fter t rauma. The c linical results were evaluated u sing University of California at Los Angeles scores (UCLA), American Shoulder and Elbow Surgeons scores (ASES) and Korean Shoulder Society scores (KSS) at 1 year after surgery.
RESULTS
Radiographic bone union was achieved at a mean of 3.7 months after the operation. In the last observation, their range of motion was forward flexion 159.0°, external rotation 59.8°, and internal rotation 4.3 points, and there were 2 cases of nonunion. Each average functional score was UCLA 31.3 points, KSS 91.6 points, and ASES 93.0 points.
CONCLUSION
For the surgical treatment of distal clavicle fractures, MTBW with additional K-wire fixation and suture is a useful technique allowing early range of motion exercises, minimizing soft tissue damage, and preserving the acromio-clavicular joint.

Citations

Citations to this article as recorded by  
  • Treatment Results for Unstable Distal Clavicle Fractures Using Hybrid Fixations with Finger Trap Wire and Plate
    Jeong-Seok Yu, Bong-Seok Yang, Byeong-Mun Park, O-Sang Kwon
    Journal of the Korean Orthopaedic Association.2022; 57(2): 135.     CrossRef
  • Comparison of Locking Compression Plate Superior Anterior Clavicle Plate with Suture Augmentation and Hook Plate for Treatment of Distal Clavicle Fractures
    Jun-Cheol Choi, Woo-Suk Song, Woo-Sung Kim, Jeong-Muk Kim, Chan-Woong Byun
    Archives of Hand and Microsurgery.2017; 22(4): 247.     CrossRef
  • 90 View
  • 1 Download
  • 2 Crossref
Close layer
Results of Tension Band Wiring and Additional Circumferential Wiring in Treatment of Comminuted Patella Fracture
Young Min Lee, Kook Jin Chung, Ji Hyo Hwang, Hong Kyun Kim, Yong Hyun Yoon
J Korean Fract Soc 2014;27(3):206-212.   Published online July 31, 2014
DOI: https://doi.org/10.12671/jkfs.2014.27.3.206
AbstractAbstract PDF
PURPOSE
The purpose of this study is to evaluate the results of tension band wiring and additional circumferential wiring in treatment of comminuted patella fractures.
MATERIALS AND METHODS
A retrospective study of 67 patients with follow-up period longer than six months who underwent tension band wiring and additional circumferential wiring for comminuted patellar fracture from January 2004 to December 2012 was conducted. Analysis was based on radiological evaluation of bony union and articular surface displacement, and clinically by evaluating the postoperative function of the knee joint using the Levack scoring system.
RESULTS
Only one case out of 67 (1.5%) showed nonunion without metal breakage while good bone union was achieved in all other cases. Excluding the nonunion case, range of motion was 90 degrees minimum, 135 maximum, 129 on average. Average displacement was less than 2 mm, and 64 out of 67 cases showed satisfactory outcome with excellent functional score according to the Levack scoring system.
CONCLUSION
Tension band wiring and additional circumferential wiring technique for treatment of comminuted patella fractures can be considered as an effective treatment for achievement of good bone union and restoration of normal knee function.

Citations

Citations to this article as recorded by  
  • A Novel Technique in Comminuted Patella Fractures: Minimally Invasive Pericerclage Osteosynthesis Using Drainage Trocar
    Fırat Fidan, Abdülkadir Polat, Cengiz Kazdal, Emre Bal
    Bakirkoy Tip Dergisi / Medical Journal of Bakirkoy.2022; 18(4): 427.     CrossRef
  • Current Treatment Strategies for Patella Fractures
    David J. Hak, Philip F. Stahel, Dustin J. Schuett, Mark E. Hake, Cyril Mauffrey, E. Mark Hammerberg, Philip F. Stahel, David J. Hak
    Orthopedics.2015; 38(6): 377.     CrossRef
  • 78 View
  • 1 Download
  • 2 Crossref
Close layer
Tension Band Wiring for Distal Clavicle Fracture: Radiologic Analysis and Clinical Outcome
Seong Cheol Moon, Chul Hee Lee, Jong Hoon Baek, Nam Su Cho, Yong Girl Rhee
J Korean Fract Soc 2014;27(2):127-135.   Published online April 30, 2014
DOI: https://doi.org/10.12671/jkfs.2014.27.2.127
AbstractAbstract PDF
PURPOSE
The purpose of this study is to evaluate the radiologic and clinical outcomes after tension band wire fixation of Neer type II distal clavicle fractures.
MATERIALS AND METHODS
Twenty-six patients with Neer type II distal clavicle fractures who underwent tension band wire fixation from March 2002 to May 2011 were included in the study. Fifteen cases were classified as Neer type IIa and 11 cases as type IIb. The postoperative mean follow-up period was 14.3 months. Clinical and radiologic evaluation was performed at two weeks, six weeks, three months, six months, and 12 months postoperatively.
RESULTS
Bony union on X-rays was observed at an average of 11.7 weeks (range 8-20 weeks) postoperatively. The overall visual analogue scale score for pain was 1.23+/-2.75 postoperatively. The overall postoperative University of California at Los Angeles score increased to 33.5+/-2.15 from the preoperative score of 21.6+/-1.91 (p<0.05).
CONCLUSION
Among various methods of treatment for Neer type II distal clavicle fracture, K-wire and tension band fixation was used and relatively satisfactory radiological and clinical results were obtained. This surgical method yields excellent clinical results, owing to its relatively easy technique, fewer complications, and allowance of early rehabilitation.

Citations

Citations to this article as recorded by  
  • Clinical and Radiologic Outcomes of Acute Acromioclavicular Joint Dislocation: Comparison of Kirschner's Wire Transfixation and Locking Hook Plate Fixation
    Yong Girl Rhee, Jung Gwan Park, Nam Su Cho, Wook Jae Song
    Clinics in Shoulder and Elbow.2014; 17(4): 159.     CrossRef
  • 120 View
  • 0 Download
  • 1 Crossref
Close layer
Circumferential Wiring Combined with Tension Band Wiring in the Operative Treatment of Patella Fracture
Jae Chun Sim, Sung Sik Ha, Ki Do Hong, Tae Ho Kim, Min Chul Sung
J Korean Fract Soc 2014;27(1):65-71.   Published online January 31, 2014
DOI: https://doi.org/10.12671/jkfs.2014.27.1.65
AbstractAbstract PDF
PURPOSE
The purpose of this study is to evaluate the radiographic and clinical results of patella fractures using a circumferential wiring combined with tension band wiring.
MATERIALS AND METHODS
Between January 2005 and June 2012, 22 (male 14, female 8) patients with patella fracture treated with circumferential wiring combined with tension band wiring were analyzed retrospectively. The mean age of patients was 51 years (range, 28 to 72 years). Controlled passive range of motion exercise was started at three weeks from the postoperative day. The patients were evaluated using radiographs, clinical examination, and Levack's scoring system.
RESULTS
All fractures healed and mean time elapsed for union was 11.5 weeks (range, 10 to 14 weeks). Complete union without displacement and full range of motion was achieved in all cases. Clinical results according to Levack's scoring system were excellent in 20 cases and good in two cases. We found broken wire in one case. In this case, results of clinical evaluation after reoperation were good.
CONCLUSION
Circumferential wiring combined with tension band wiring is appropriate for patella fractures.

Citations

Citations to this article as recorded by  
  • Patellar fracture fixation using cannulated screws and Fiber Wire tension band
    Elsayed M Bayomy, Mohamed Y Shaheen
    Egyptian Orthopaedic Journal.2023; 58(1): 15.     CrossRef
  • 82 View
  • 0 Download
  • 1 Crossref
Close layer
Double Tension Band Wiring for Olecranon Fractures
Suk Kang, Chung Soo Hwang, Phil Hyun Chung, Young Sung Kim, Jin Wook Chung, Jong Pil Kim
J Korean Fract Soc 2008;21(2):130-134.   Published online April 30, 2008
DOI: https://doi.org/10.12671/jkfs.2008.21.2.130
AbstractAbstract PDF
PURPOSE
To evaluate the clinical results of double tension band wiring for communited olecranon fractures involving proximal 1/3.
MATERIALS AND METHODS
We reviewed 9 cases of communited olecranon fractures involving proximal 1/3 treated with double tension band wiring followed for minimum 10 months. There were 2 cases of olecranon fractures involving only proximal 1/3, 6 cases of olecranon fractures involving from proximal 1/3 to middle 1/3 and 1 case of olecranon fractures involving from proximal 1/3 to distal 1/3. We analyzed the bone union time, radiologic results for gap, reduction loss, pin migration, pain, range of motion, complications and functional outcomes at last follow up.
RESULTS
All patients had solid bone union without additional surgery and average union time was 10.3 weeks. Anatomical reduction could be obtained in 8 of 9 cases but there was 1 mm step off in one case. 36 pins were used to fix the fractures, 1 pin of 18 distal pins and 2 pins of 18 proximal pins were migrated to backward but there was no reduction loss. Only 1 distal pin needed early removal due to skin irritation. Average range of motion ranged from flexion contracture 3.3 degrees to further flexion 137.8 degrees. On functional analysis, we got 8 cases of good result, 1 case of fair result and there was no poor result.
CONCLUSION
Double tension band wiring for comminuted olecranon fracture involving proximal 1/3 was concluded to give a firm fixation of the fracture site as bone union could be acquired without serious pin problems.

Citations

Citations to this article as recorded by  
  • Treatment of Olecranon Fractures with Proximal Ulna Comminution Using Locking Compression Plates
    Ki-Do Hong, Tae-Ho Kim, Jae-Cheon Sim, Sung-Sik Ha, Min-Chul Sung, Jong-Hyun Jeon
    Journal of the Korean Fracture Society.2015; 28(1): 59.     CrossRef
  • Olecranon Nonunion after Operative Treatment of Fracture
    Ho-Jung Kang, Ji-Sup Kim, Myung-Ho Shin, Il-Hyun Koh, Yun-Rak Choi
    Journal of the Korean Fracture Society.2015; 28(1): 30.     CrossRef
  • 65 View
  • 0 Download
  • 2 Crossref
Close layer
Modified Phemister Technique with Tension Band Wiring in Acromioclaviculr Joint Dislocation
Yu Jin Kim, Hun Kyu Shin, Ji Won Lee
J Korean Fract Soc 2006;19(4):431-436.   Published online October 31, 2006
DOI: https://doi.org/10.12671/jkfs.2006.19.4.431
AbstractAbstract
PURPOSE
To evaluate the clinical and radiological result of surgical treatment of acromioclavicular joint dislocation, using modified Phemister technique with tension band wiring.
MATERIALS AND METHODS
We chose 17 patients who were able to follow up 1 year or more among the patients who were diagnosed as acromioclavicular joint dislocation in our hospital through January 2000 to Feburary 2005 and took modified Phemister technique with tension band wiring. Evaluation of the surgical results was done with the condition of pain, activity of daily living, range of motion, muscle tone by constant score system, and with preoperative, postoperative and last follow up radiographs.
RESULTS
Clinical evaluation was average 92 point by Constant score system from 84 point to 100 point. Subjective evaluation was 11 excellent (65%), 6 good (35%). Radiological evaluation was 9 excellent (54%), 6 good (38%), 2 fair (12%), and no poor group. On the final follow up, two cases showed inflammatory reaction at where pins were inserted, but after the removal of the pins, the inflammation was subsided.
CONCLUSION
The modified Phemister surgery for acromioclavicular dislocation is one of effective techniques, we can obtain firm fixation, exercise full range of motion early and there is no complication of re-dislocation.
  • 86 View
  • 0 Download
Close layer
The Treatement of the Unstable Proximal Humerus Fracture Using Bifurcate Angled Blade Plate with Tension Band Wiring
Kuen Tak Suh, Hyoung Lok Roh, Myung Soo Youn, Jung Sub Lee
J Korean Fract Soc 2006;19(4):424-430.   Published online October 31, 2006
DOI: https://doi.org/10.12671/jkfs.2006.19.4.424
AbstractAbstract
PURPOSE
To evaluate the results of internal fixation with bifurcate angled blade plate and tension band wiring of greater tuberosity or rotator cuff for the unstable proximal humerus fracture.
MATERIALS AND METHODS
Nineteen cases of unstable proximal humerus fracture who were followed up for more than 1 year were treated using bifurcate angled blade plate and tension band wiring between March 2003 and March 2005. Average age of the patients was 46.5 years (range, 24 to 69), and there were 9 male and 10 female patients. The radiological results were evaluated by bony union and neck shaft angle. In addition, the clinical results were evaluated by Neer's evaluation criteria.
RESULTS
In 18 out of 19 cases, bony union was obtained in average 12.5 weeks after operation. The neck shaft angles of sixteen cases were between 120 and 140 degrees by Paavolainen method. According to Neer's evaluation criteria, 17 cases showed excellent or good results.
CONCLUSION
The patients treated using bifurcate angled blade plate and tension band wiring could exercise earlier because of good initial stability. Also, the radiological and clinical results were relatively good. The treatment of unstable proximal humerus fracture with bifurcate angled blade plate and tension band wiring was considered as a good method.

Citations

Citations to this article as recorded by  
  • Hemiarthoplasty with Bone Block Graft and Low Profile Prosthesis for the Comminuted Proximal Humerus Fractures
    Chung Hee Oh, Joo Han Oh, Sae Hoon Kim, Ki Hyun Jo, Sung Woo Bin, Hyun Sik Gong
    Journal of the Korean Fracture Society.2008; 21(3): 213.     CrossRef
  • 114 View
  • 0 Download
  • 1 Crossref
Close layer
Modified Tension Band Wiring using Cortical Screw for Medial Malleolar Fractures
Ho Rim Choi, Hyun Woo Doh, Byoung Heum Kim, Kyou Hyeun Kim, Jong Seok Park, Joon Min Song
J Korean Fract Soc 2004;17(4):319-322.   Published online October 31, 2004
DOI: https://doi.org/10.12671/jkfs.2004.17.4.319
AbstractAbstract PDF
PURPOSE
To evaluate the clinical results of modified tension band wire technique using cortical screw for treatment of displaced medial malleolar fractures of the ankle.
MATERIALS AND METHODS
From January 2001 to January 2003, 24 patients were treated by modified tension band wiring using cortical screw for medial malleolar fracture. The follow-up period was 12~35 months (average 18 months). There were 13 males and 11 females, and the mean age was 46 years. Fractures were classified by Lauge-Hansen's classification. The results were analyzed by Meyer and Kumler's criteria.
RESULTS
There were 13 cases (54%) of excellent, 9 cases (38%) of good, and one case of fair because of limitation of motion of the ankle joint and one case of poor which showed post-traumatic arthritis of the ankle.
CONCLUSION
Modified tension band wire technique using cortical screw can be an effective operative method for the treatment of displaced medial malleolar fractures of the ankle.
  • 87 View
  • 0 Download
Close layer
The Treatment of Patellar Fracture with Modified Tension Band Wiring, using Cannulated Screws
Chul Won Ha, Jong Il Sun
J Korean Fract Soc 2004;17(2):117-121.   Published online April 30, 2004
DOI: https://doi.org/10.12671/jkfs.2004.17.2.117
AbstractAbstract PDF
PURPOSE
We have followed up the patients of the patellar fracture who had been treated with modified tension band wiring using cannulated screws. Since we have seen excellent clinical results, we would like to show the practical use of this operative method.
MATERIALS AND METHODS
We analyzed the operation time, the time elapsed for union, and complications of 9 cases of the patellar fracture who were treated with this operative method at our hospital recently.
RESULTS
Mean operation time (from the incision to the skin suture) was 68.3 min (40~120 min) and mean time elapsed for union was 9.7 weeks (8~12 wks). Mean time for full range of motion was 1 week in 5 cases of transverse fracture, 3 weeks (2~4 wks) in 3 cases of comminuted fracture. We found no complications like limitation of range of motion of the knee, loss of the reduction, irritation and migration of the hardware, and infection.
CONCLUSION
This surgical technique provides stable fixation, allowes early motion excercise by minimizing injury to extensor mechanism and accompanies reduced rate of complications such as loss of the reduction, irritation or displacement of the hardware

Citations

Citations to this article as recorded by  
  • Evolution in the Management of Patella Fractures
    Mahak Baid, Sid Narula, Jonathan R. Manara, William Blakeney
    Journal of Clinical Medicine.2024; 13(5): 1426.     CrossRef
  • Results of Tension Band Wiring and Additional Circumferential Wiring in Treatment of Comminuted Patella Fracture
    Young Min Lee, Kook Jin Chung, Ji Hyo Hwang, Hong Kyun Kim, Yong Hyun Yoon
    Journal of the Korean Fracture Society.2014; 27(3): 206.     CrossRef
  • Treatment of Transverse Patellar Fracture with Cannulated Screws
    Jung-Man Kim, Ju-Seok Yoo, Yong-Jin Kwon, Jang-Ok Cheon
    Journal of the Korean Fracture Society.2007; 20(2): 149.     CrossRef
  • 114 View
  • 1 Download
  • 3 Crossref
Close layer
Treatment of Distal Clavicle Type II Fracture using K-Wires and Tension Band Wiring
Whan Yong Chung, Woo Suk Lee, Taek Soo Jeon, Dae Hwan Kim, Kwang Kyoon Kim, Jae Woo Lim
J Korean Soc Fract 2003;16(2):215-221.   Published online April 30, 2003
DOI: https://doi.org/10.12671/jksf.2003.16.2.215
AbstractAbstract PDF
PURPOSE
This is a retrospective study to analyze the clinical results of the usefulness of K-wires and tension band wiring that fix the fracture fragment directly without passing the acromioclavicular joint in distal clacivle type II fractures.
MATERIALS AND METHODS
From May 2000 to May 2001, eleven patients with distal clavicle type II fracture were treated by open reduction and internal fixation with K-wires and tension band wiring. The clinical results were analyzed according to modified shoulder rating scale for distal clavicle freacture. Radiological union, complication, and range of motion of the shoulder were assessed.
RESULTS
All fractures were united at 10 weeks (8~12 weeks) in average. Finally, full range of motion of the shoulder joint was achieved in all patients. No complication was found and the modified shoulder rating scale for distal clavicle fracture were as follows: excellent 9 and good 2.
CONCLUSION
K-wires and tension band wiring can be a good treatment method for distal clavicle type II fractures.

Citations

Citations to this article as recorded by  
  • Tension Band Wiring for Distal Clavicle Fracture: Radiologic Analysis and Clinical Outcome
    Seong Cheol Moon, Chul Hee Lee, Jong Hoon Baek, Nam Su Cho, Yong Girl Rhee
    Journal of the Korean Fracture Society.2014; 27(2): 127.     CrossRef
  • 104 View
  • 0 Download
  • 1 Crossref
Close layer
Modified Tension Band Wiring using Cortical Screw for Displaced Medial Malleolar Fractures
Jong Oh Kim, Sang Hun Ko
J Korean Soc Fract 2002;15(4):459-464.   Published online October 31, 2002
DOI: https://doi.org/10.12671/jksf.2002.15.4.459
AbstractAbstract PDF
PURPOSE
To evaluate the clinical results of minimal incision and modified tension band wiring using 3.5mm cortical screw in the treatment of ankle fracture including displaced medial malleolar fractures MATERIALS AND METHODS: From March 1997 to May 2001, 77 patients were treated by modified tension band wiring using minimal incision about 4cm for medial malleolar fracture.
RESULTS
According to Lauge-Hansen classification, there were 47 supination-external rotation type fractures (61%), 14 supination -adduction type fractures (18.2%), 10 pronation-external rotation type(12.9%), 6 pronation-abduction type fracture(7.8%). The average time to union was 12.5weeks. In the functional outcome (according to Meyer and Kumler), 71 patients(92%) showed excellent results.
CONCLUSION
We concluded that modified tension band wiring using cortical screw proved effective fixation method in the treatment of the displaced medial malleolar fracture. The merits of this procedure are minimal incision about 4cm and preservation of blood supply on suprafracture area due to not injuried periosteum, stable fixation and early range of motion of joint, simple procedure and reduced surgical time.
  • 33 View
  • 0 Download
Close layer
Treatment of patellar Fractures with Modified Tension Band Wiring
Myung Hwan Son, Byung Chul Kim, Nam Wook Kang, Tae Young Choi
J Korean Soc Fract 1999;12(4):872-878.   Published online October 31, 1999
DOI: https://doi.org/10.12671/jksf.1999.12.4.872
AbstractAbstract PDF
The aim of treatment of patellar fracture is the restoration of knee joint function and quadriceps muscle power. Comminuted and displaced fracture of the patella, which are difficult to reduce accurately and to get stable internal fixation, may lead to traumatic osteoarthritis, chondromalacia, limited ROM of the knee joint. In this series, we treated 29 cases of displaced transverse and comminuted fractures with modified tension band wiring. In severely comminuted fractures, the fragments were indirectly reduced by cerclage wire and then fixed with modified tension band wiring. We could obtain stable fixation and early ROM of the knee joint. There were 5 complications including wire breakage and wire loosening. In this respect, we concluded that modified tension band wiring was a good method for displaced transverse and comminuted patellar fracture.

Citations

Citations to this article as recorded by  
  • Circumferential Wiring Combined with Tension Band Wiring in the Operative Treatment of Patella Fracture
    Jae-Chun Sim, Sung-Sik Ha, Ki-Do Hong, Tae-Ho Kim, Min-Chul Sung
    Journal of the Korean Fracture Society.2014; 27(1): 65.     CrossRef
  • 123 View
  • 1 Download
  • 1 Crossref
Close layer
Operative Treatment of patellar Fractures
Chang Kwan Kim, Jeong Hwan Kim, Sang Yup Lee, Young Hwan Kim, Chae Ik Chung, Jeong Gee Hong
J Korean Soc Fract 1999;12(4):858-864.   Published online October 31, 1999
DOI: https://doi.org/10.12671/jksf.1999.12.4.858
AbstractAbstract PDF
We studied 45 patients of patella fracture who were treated by surgical method from March 1990 to December 1991. The results were analysed to evaluate the functional results of the knee according to methods of fixation and severity of comminution. The results were as follows. 1. Out of 45 cases, 11 cases were tredted by tension band wiring, 19 cases by modified tension band wiring, 5 cases by tension band wiring by circumferential wiring, 8 cases by circumferential wiring, and 2 cases by screw fixation. 2. The mean fracture healing period was 6.9 weeks in cases of tension band wiring, 6.5 weeks in cases of modified tension band wiring, 5.2 weeks in cases of tension band wiring with circumferential wiring, and 7.3 weeks in cases of circumferential wiring. 3. The most favorable result was obtained in cases which were fixed with tension band wiring and circumferential wiring. 4. Modified tension band wiring seems to be a good method for displaced transverse fracture and comminuted fracture with large fragments and tension band wiring with circumferential wiring is for severely comminuted fracture with small fragments.
  • 87 View
  • 0 Download
Close layer
Case Report
Osteochondral Avulsion Fracture in Patella after Treatment of Abscess around Knee: A Case report
Keun Soo Lee, Geon Woo Lee, Sang Ho Song, Hyun Seo
J Korean Soc Fract 1999;12(2):290-293.   Published online April 30, 1999
DOI: https://doi.org/10.12671/jksf.1999.12.2.290
AbstractAbstract PDF
Osteochondral avulsion fracture of patella has been rarely reported. We experienced one case of osteochondral avulsion fracture which was developed after abscess around knee. The patient was a 16year old with the history of abscess. The presenting symptom was knee pain and loss of extension power. Radiologic and operative findings suggested that osteochondral avulsion fracture of the patella, was caused by minor trauma near the insertion site of quadriceps tendon. In usual case of quadriceps tendon rupture, the rupture occurred at the musculotendinous junction, caused by sudden contracture of the muscle without trauma history. This case was treated successfully with tension band wiring technique. Differential diagnosis between osteochondral avulsion fracture and osteomyelitis of patella was emphasized.
  • 96 View
  • 0 Download
Close layer
Original Articles
Treatment of Patella Fracture Using Modified Transverse Tension Band Wiring Method
Jung Dae Oh, Cyeong Rim Lim, Yu Jin Joung, Gyu Sung Lee
J Korean Soc Fract 1998;11(4):858-864.   Published online October 31, 1998
DOI: https://doi.org/10.12671/jksf.1998.11.4.858
AbstractAbstract PDF
Recently the fracture of patella has increasing tendency due to frequent traffic and industrial accidents. In this series, we treated fractures of patella by open reduction and internal fixation with modified transverse tension band wiring method. Early post operative continuous passive motion and early weight bearing exercise were followed. This method was excellent for treatment of the patella fractures. The surgical results were evaluted by Leveck scoring systems, 12 out of 14 cases had satisfactory results. This technique have some advantage in terms of decreasing pain and maintenance of circulation on the patella, because of the small incision and minimize dissection. It can prevent post operative complications such as limitation of motion and post traumatic arthritis of the knee joint.
  • 93 View
  • 0 Download
Close layer
Operative Treatment of Olecranon Fractures Using Tension Band Wiring
Hyun Dae Shin, Kwang Jin Rhee, June Kyu Lee, Joon Uoung Uang, Young Mo Kim, Mun Jong Lee, Jin Soo Kim
J Korean Soc Fract 1998;11(3):672-682.   Published online July 31, 1998
DOI: https://doi.org/10.12671/jksf.1998.11.3.672
AbstractAbstract PDF
We treated 26 cases(25 patients) olecranon fractures operatively with Kirschner wire and tension band wiring technique from January 1993 to December 1995. The Kirschner wire fixation methods in our study were either bicortical fixation(15 cases) or intramedullary fixation(11 cases). We retrospectively reviewed clinical results according to Mayo elbow performance index and starting time of full range of motion(ROM) exercise. We analyzed relationship between the cli9nical results of the cases with cast immobilization and those without cast immobilization. We also compared Kirschner wire fixation methods in the respect of clinical results, full ROM exercise starting time and complications. The results were as follows. 1. Clinical results were excellent or good in 25 cases(96%) according to Mayo elbow performance index. Full ROM exercise starting time was within 2weeks in 10 cases, between 2-3weeks in 11 cases, between 5-6weeks in four cases and after 6weeks in one case. Full ROM exercise starting time was significantly different(P=0.016) with clinical results statistically and there was statistically high significant difference(P=0.0025) between clinical results and cast immobilization or not. 2. Clinical results of bicortical fixation group was ont significantly different frmo those of intramedullary fixation group and there was no significant difference between full ROM exercise starting time and Kirschner fixation methods statistically. 3. The most frequent complications were decreased ROM and loosening of the Kirschner wire. There were decreased ROM In 10 cases and loosening of the Kirschner wire in 6 cases in all cases. We encountered more higher incidence of complications related to intramedullary fixation method. The clinical results and full ROM exercise starting time of bicortical fixation group were not significantly different with those of intramedullary fixation group statistically. But more early exercise, more better clinical results and more less complications was produced in bicortical fixation group. So we thought bicortical fixation method is better than intramedullary fixation method.

Citations

Citations to this article as recorded by  
  • Double Tension Band Wiring for Olecranon Fractures
    Suk Kang, Chung Soo Hwang, Phil Hyun Chung, Young Sung Kim, Jin Wook Chung, Jong Pil Kim
    Journal of the Korean Fracture Society.2008; 21(2): 130.     CrossRef
  • 105 View
  • 0 Download
  • 1 Crossref
Close layer
Treatment of Cubitus Varus Using Tension Band Wiring after the Supracondylar Osteotomy
Dne Yong Han, Hui Wan Park, Dong Eun Shin, Ki Won Suh
J Korean Soc Fract 1997;10(3):678-684.   Published online July 31, 1997
DOI: https://doi.org/10.12671/jksf.1997.10.3.678
AbstractAbstract PDF
Cubitus varus is the most common angular deformity that results from supracondylar fractures in children. Although this deformity rarely limit elbow function, the correction is frequently requested due to cosmetic problem. This paper was prepared to describe the operative method and to evaluate the clinical results of tension band wirinB after distal humeral supracondylar osteotomy for cubitus varus. The result was evaluated using Oppenheim criteria. Excellent or good cases were 94.4%. We concluded that tension band wiring is a satisfactory method of treatment for cubitus varus.

Citations

Citations to this article as recorded by  
  • Evaluation of tension-band osteosynthesis for cubitus varus deformity in pediatric patients: A retrospective review
    Man Duc Minh Phan, Terry Richard Light, Tiep Van Phan, Phi Duong Nguyen
    Journal of Hand and Microsurgery.2025; 17(2): 100213.     CrossRef
  • 50 View
  • 1 Download
  • 1 Crossref
Close layer
Fracture of Olecranon Treated by K-wire and Tension Band Wiring Technique in Adults
Hak Yeong Jeong, Seung Wook Yang, Jae Woong Shim, Beyong Seon Kong
J Korean Soc Fract 1997;10(3):651-657.   Published online July 31, 1997
DOI: https://doi.org/10.12671/jksf.1997.10.3.651
AbstractAbstract PDF
Displaced fractures of olecranon in adults require operative treatment. The goal of treatment is to rigidly fix the fracture fragment, to anatomically restore the joint surface and to allow range of motioin early. Authors treated fractures of olecranon by open reduction and internal fixation using K-wire and tension band wiring technique in 38 adult patients from April 1989 to October 1995 at the Department of Orthopedic Surgery, Maryknoll Hospital. This article documents the study of relationship between the treatment result and involvement of articular surface, articular step-off and gap of articular surface. The results were as follows ; 1. The clinical results were good or fair in 31 cases(82%) according to the criteria by Helm et al. 2. Involvement of articular surface, step-off and gap of articular surface affected the results. 3. The clinical results were satisfactory in patients with postoperative step-off less than 2mm and postoperative gap of articular surface less than 2mm. 4. The clinical results were satisfactory in patients with articular involvement less than 60%.
  • 79 View
  • 0 Download
Close layer
Operative Treatment of Comminuted Fraeture of the Patella
Yung Khee Chung, Jung Han Yoo, Yong Wook Park, Gyu Cheol Roh
J Korean Soc Fract 1996;9(4):970-976.   Published online October 31, 1996
DOI: https://doi.org/10.12671/jksf.1996.9.4.970
AbstractAbstract PDF
The patella, lying within the quadriceps tendon mechanism and subcutaneous in position, is susceptible to the effects of both direct and indirect trauma. Patella fractures are intra-articular injuries and have a significant effect on knee function. The tension band wiring technique is widely used for treating fractures of the patella and is often the treatment of choice. We reviewed tweenty nine cases of cemminuted fracture of the patella treated with surgical methods from Jan. 1989 to Mar. 1995 and fellowed up more than one year, from the department of of hopedic surgiry, Kangnam Sacred Heart Hospital, Hallym University. The results were as follows: 1. According to the classincation of Bostman, there were 6 cases(20.7%) of type 1.16(55.2%) of II A, 5(17.2%) of II B and 2(6.9%) of III. 2. Of tweenty nine cases, tweenty six(89.7%) were treated by modified tension band wiring with cerclage wiring (MTBW with CW) and three(10.3%) by partial patellectomy with cerclage wiring(PP with CW). 3. Among tweenty six cases treated with MTBW with CW. tweenty one cases(76.9%) revealed a good or exellent result according to the Cincinnati rating system. 4. Especially, among 5 cases of type II B & 2 cases of type III comminuted fracture treated with MTBW with CW, 5 cases(73.4%) revealed good result. We concluded that the use of modified tension band wiring with cerclage wiring for the comminuted fracture of patella has been shown to be a satisfactory method.

Citations

Citations to this article as recorded by  
  • Results of Tension Band Wiring and Additional Circumferential Wiring in Treatment of Comminuted Patella Fracture
    Young Min Lee, Kook Jin Chung, Ji Hyo Hwang, Hong Kyun Kim, Yong Hyun Yoon
    Journal of the Korean Fracture Society.2014; 27(3): 206.     CrossRef
  • 64 View
  • 0 Download
  • 1 Crossref
Close layer
Operative Treatment of Patellar Fracutres
Eun Kyoo Song, Dae Ik Kim, Hyung Seog Kim
J Korean Soc Fract 1996;9(3):640-646.   Published online July 31, 1996
DOI: https://doi.org/10.12671/jksf.1996.9.3.640
AbstractAbstract PDF
Patella has important roles to enhance extensor mechanism of knee, therefore patellar fractures should be treated correctly according to the type and displacement of fractures for the preservation of patellar function. The purpose of study is to analyse the clinical results of operative treatment for patellar fractures. 77 cases of patellar fracture which were treated at Chonnam University Hospital between June 1985 and March 1995 were reveiwed. Among them, 32 cases with open reduction and internal fixation were included in this study. The mean follow-up period was 21.5 months(range twelve to eighty two months). Oircurnferential wiring, modified tension band wiring, malleolar screws and combination of circlage and tension band wiring were used as a fixatives. The clinical results were compared according to Reileys clinical evaluation criteria mainly by range of motions, mid-thigh circumferential difference. The most favorable results could be obtained with the combination of circlage and tension band wiring.
  • 83 View
  • 0 Download
Close layer
Surgical Treatment of the Patellar Fractures
Hak Yeong Jeong, Seung Wook Yang, Young Cheol Shin, Han Sung Park, Tae Ho Joo
J Korean Soc Fract 1995;8(3):578-585.   Published online July 31, 1995
DOI: https://doi.org/10.12671/jksf.1995.8.3.578
AbstractAbstract PDF
Recently the incidence of the patellar fracture has been increasing because of frequent traffic accidents and industrial accidents, and its treatment is considered very important due to the involvement of the articular suface occurs in most of the cases. Comminuted displaced fractures of the patella which are difficult to reduce accurately and to get stable internal fixation, may lead to traumatic osteoarthritis, chondromalacia, extension lag and limited ROM of the knee joint. The retrospective review was undertaken of 49 patients with patellar fractures treated by surgical methods and a follow up of more than 1 year at the Department of Orthopaedic Surgery at Maryknoll Hospital between Aug. 1987 and Jan. 1994. The findings were as follows: 1. Most fractures were encountered in man from twenties to forties. 2. The most common cause of fractures was traffic accident, followed by slip down or fall down. 3. Comminuted fracture was the most common type in this series. 4. Large separated fragments of the patella should be accurately reduced with rigid fixation in the rationale of the intraarticular fracture. 5. The most favorable results were obtained by Modified Tension Band Wiring with supplementary oircurnferential wiring for comminuted fractures and the result was superior to other operative methods.
  • 87 View
  • 0 Download
Close layer
Modified tension band wiring and Circumferential wiring in the operative treatment of patella fracture
Hyung Seok Kim, Ki Do Hong, Sung Sik Ha, Young Keun Park, Nam Sik Chung
J Korean Soc Fract 1994;7(2):522-529.   Published online November 30, 1994
DOI: https://doi.org/10.12671/jksf.1994.7.2.522
AbstractAbstract PDF
The patella, the largest human sesamoid bone, lies within and is important functional component of the knee extensor mechanism, So the treatment of patellar fracture is considered very important. In this series, we experiened 24 cases of ptellar fractures treated with modified tension band wiring and circumferential wiring from Jan. 1987 to Dec. 1992 at the department of orthopaedic surgery, Seoul Adventist Hospital. The Results were as follows; 1. The mean fracture healing peroid was 9.6 weeks in cases of modified tension band wiring and 12.4 weeks in circumferential wiring. 2. circumferential wiring is a good method for severe comminuted, small fragmented fracture and modified tension band wiring is for displaced transeverse fracture and large fragmented comminuted feacture.
  • 85 View
  • 0 Download
Close layer
Tension Band Wiring with Anchoring Screw in Medial Malleolar Fracture
Young Won Rho, Taik Keun Ahn, Jong Oh Kim, Taik Seon Kim, Jai Ik Shim
J Korean Soc Fract 1990;3(2):247-251.   Published online November 30, 1990
DOI: https://doi.org/10.12671/jksf.1990.3.2.247
AbstractAbstract PDF
Since development of sports and leisure, ankle fracture occurs frequently. The goal of treatment of ankle fracture is anatomic restoration of ankle joint. With introduction of tension band wiring technique by A-O group, this technique was used popularly. The authors reported 15 cases of medial malleolar fracture in which patients were treated by tension band wiring with anchoring of screw instead of primary osseous tunnel, from September 1987 to August 1989. The advantage of modified tension band wiring technique is shortening of operative time and simplicity of technique.
  • 89 View
  • 0 Download
Close layer
Tension band wiring and Modified tension band wiring in the Operative Treatment of Patella Fracture
Sang Ho Ha, Sang Hong Lee, Dong Min Shin, Young Bae Pyo
J Korean Soc Fract 1990;3(1):46-52.   Published online May 31, 1990
DOI: https://doi.org/10.12671/jksf.1990.3.1.46
AbstractAbstract PDF
The authors report a clinical experience of 25 patients having patellar fracture who were treated with tension band wiring or modified tension band wiring from January 1984 to December 1988, at the Department of Orthopedic Surgery, Cho-Sun University Hospital. The results were as follows. 1. Out of 25 cases were treated by modified tension band wiring and remaining 5 cases were treated by tension band wiring. 2. The mean fracture healing period was 5.8 weeks in cases of modified tension band wiring and 6.8 weeks in tension band wiring. 3. Fixation by tesion band priciple has given acceptable results in comminuted fractures and transverse fractures both.
  • 93 View
  • 0 Download
Close layer
Treatment of Patella Fracture Using Wiring Method
Kwon Ick Ha, Sung Ho Hahn, Min Young Chung, Hyun Soo Park
J Korean Soc Fract 1989;2(2):229-233.   Published online November 30, 1989
DOI: https://doi.org/10.12671/jksf.1989.2.2.229
AbstractAbstract PDF
To determine whether any of the commomly used wiring technique are rigid enough to allow early motion in treatment of patellar fracture. Twelve cases of extensively commivuted and displaced patellar fracture were treated using wire technique (circumferential combined tension band wiring) at N.P.H. from April 1987 to April 1989. This method has advatages of simple and rigid fixation and results were satisfactory.

Citations

Citations to this article as recorded by  
  • Results of Tension Band Wiring and Additional Circumferential Wiring in Treatment of Comminuted Patella Fracture
    Young Min Lee, Kook Jin Chung, Ji Hyo Hwang, Hong Kyun Kim, Yong Hyun Yoon
    Journal of the Korean Fracture Society.2014; 27(3): 206.     CrossRef
  • 86 View
  • 0 Download
  • 1 Crossref
Close layer

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
Close layer
TOP