Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 15(4); 2002 > Article
Original Article
Modified Tension Band Wiring using Cortical Screw for Displaced Medial Malleolar Fractures
Jong Oh Kim, Sang Hun Ko
Journal of the Korean Society of Fractures 2002;15(4):459-464.
DOI: https://doi.org/10.12671/jksf.2002.15.4.459
Published online: June 17, 2016

Department of Orthopedic Surgery, School of Medicine, Ewha Woman 's University, Korea.

Department of Orthopedic Surgery, Bundang Jesaeng Hospital, Daejin Medical Center, Kyungki Do, South Korea.

shko@dmc.or.kr

Copyright © The Korean Fracture Society

  • 33 Views
  • 0 Download
prev next
  • PURPOSE: To evaluate the clinical results of minimal incision and modified tension band wiring using 3.5mm cortical screw in the treatment of ankle fracture including displaced medial malleolar fractures MATERIALS AND METHODS: From March 1997 to May 2001, 77 patients were treated by modified tension band wiring using minimal incision about 4cm for medial malleolar fracture. RESULTS: According to Lauge-Hansen classification, there were 47 supination-external rotation type fractures (61%), 14 supination -adduction type fractures (18.2%), 10 pronation-external rotation type(12.9%), 6 pronation-abduction type fracture(7.8%). The average time to union was 12.5weeks. In the functional outcome (according to Meyer and Kumler), 71 patients(92%) showed excellent results. CONCLUSION: We concluded that modified tension band wiring using cortical screw proved effective fixation method in the treatment of the displaced medial malleolar fracture. The merits of this procedure are minimal incision about 4cm and preservation of blood supply on suprafracture area due to not injuried periosteum, stable fixation and early range of motion of joint, simple procedure and reduced surgical time.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Modified Tension Band Wiring using Cortical Screw for Displaced Medial Malleolar Fractures
        J Korean Soc Fract. 2002;15(4):459-464.   Published online October 31, 2002
        Close
      • XML DownloadXML Download
      We recommend
      Modified Tension Band Wiring using Cortical Screw for Displaced Medial Malleolar Fractures
      Modified Tension Band Wiring using Cortical Screw for Displaced Medial Malleolar Fractures

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP