Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Articles

Page Path
HOME > J Musculoskelet Trauma > Volume 27(4); 2014 > Article
Original Article
A Retrospective Comparative Study of Internal Fixation with Reconstruction Plate Versus Anatomical Locking Compression Plate in Displaced Intercondylar Fractures of Humerus
Tong-Joo Lee, M.D., Ph.D., Young-Tae Kim, M.D., Dae-Gyu Kwon, M.D., Ju-Yong Park, M.D.
Journal of the Korean Fracture Society 2014;27(4):294-300.
DOI: https://doi.org/10.12671/jkfs.2014.27.4.294
Published online: October 20, 2014

Department of Orthopedic Surgery, Inha University School of Medicine, Incheon, Korea.

Address reprint requests to: Tong-Joo Lee, M.D., Ph.D. Department of Orthopedic Surgery, Inha University Hospital, 27 Inhang-ro, Jung-gu, Incheon 400-711, Korea. Tel: 82-32-890-3043, Fax: 82-32-890-3047, TJLEE@inha.ac.kr
• Received: December 30, 2013   • Revised: May 19, 2014   • Accepted: August 10, 2014

Copyright © 2014 The Korean Fracture Society. All rights reserved.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 24 Views
  • 0 Download
prev next
  • Purpose
    To analyze the clinical result of a conventional reconstruction plate (CRP) fixation and locking compressive plate (LCP) fixation on the surgical treatment of an adult's displaced intercondylar fracture of humerus.
  • Materials and Methods
    A total of 40 patients enrolled in the study were treated between August 2002 and May 2012. Fixation with a CRP was performed in 20 patients (group A) and anatomical locking compression plate fixation was performed in 20 patients (group B). The clinical and functional evaluation was performed according to the Mayo elbow performance score and Cassebaum classification of elbow range of motion (ROM), disabilities of the arm, shoulder and hand score.
  • Results
    The Mayo elbow functional evaluation scores, eight cases were excellent, 10 cases were good, and two cases were fair in group A, and 12 cases were excellent, seven cases good, and one case fair in group B; both groups showed satisfactory results. The durations of attaining 90 to 120 degrees of the ROM of joints postoperatively were 8.3 days on average (6 to 15 days) in group A and 5.5 days on average (5 to 9 days) in group B, demonstrating a significant difference between the two groups (p=0.04). Although the correlations of clinical results according to the difference of bone mineral densities (BMDs) were not statistically significant between the two groups (p=0.35), loss of fixation occurred due to loosening of screws in two patients with low BMDs in whose operations reconstruction plates were used.
  • Conclusion
    The use of locking compressive plate on the surgical treatment of an diaplaced intercondylar fracture of humerus have a good clinical results because that permits early rehabilitation through good fixation and reduces the complications such as loosening of screws.
  • 1. Helfet DL, Schmeling GJ. Bicondylar intraarticular fractures of the distal humerus in adults. Clin Orthop Relat Res, 1993;(292):26-36.
  • 2. Henley MB. Intra-articular distal humeral fractures in adults. Orthop Clin North Am, 1987;18:11-23.
  • 3. Kang CN, Wang JM, Roh KJ, Yun YH, Cho DY. Multiple K Wires fixation of the intercondylar fracture of humerus in adults. J Korean Soc Fract, 1993;6:325-330.
  • 4. Papaioannou N, Babis GC, Kalavritinos J, Pantazopoulos T. Operative treatment of type C intra-articular fractures of the distal humerus: the role of stability achieved at surgery on final outcome. Injury, 1995;26:169-173.
  • 5. Greiner S, Haas NP, Bail HJ. Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system. Arch Orthop Trauma Surg, 2008;128:723-729.
  • 6. Horne G. Supracondylar fractures of the humerus in adults. J Trauma, 1980;20:71-74.
  • 7. Jupiter JB. Complex fractures of the distal part of the humerus and associated complications. Instr Course Lect, 1995;44:187-198.
  • 8. O'Driscoll SW, Jupiter JB, Cohen MS, Ring D, McKee MD. Difficult elbow fractures: pearls and pitfalls. Instr Course Lect, 2003;52:113-134.
  • 9. Ring D, Gulotta L, Roy A, Jupiter JB. Concomitant nonunion of the distal humerus and olecranon. J South Orthop Assoc, 2003;12:27-31.
  • 10. Ring D, Jupiter JB. Complex fractures of the distal humerus and their complications. J Shoulder Elbow Surg, 1999;8:85-97.
  • 11. Schuster I, Korner J, Arzdorf M, Schwieger K, Diederichs G, Linke B. Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities. J Orthop Trauma, 2008;22:113-120.
  • 12. Aitken GK, Rorabeck CH. Distal humeral fractures in the adult. Clin Orthop Relat Res, 1986;(207):191-197.
  • 13. Gabel GT, Hanson G, Bennett JB, Noble PC, Tullos HS. Intraarticular fractures of the distal humerus in the adult. Clin Orthop Relat Res, 1987;(216):99-108.
  • 14. Shin R, Ring D. The ulnar nerve in elbow trauma. J Bone Joint Surg Am, 2007;89:1108-1116.
  • 15. Wang KC, Shih HN, Hsu KY, Shih CH. Intercondylar fractures of the distal humerus: routine anterior subcutaneous transposition of the ulnar nerve in a posterior operative approach. J Trauma, 1994;36:770-773.
Fig. 1
One case from group A. (A) Initial radiographs show AO/ASIF type C2 fracture of the distal humerus. (B) Postoperative radiographs show a bilateral reconstruction plate through chevron osteotomy of olecranon. (C) At postoperative one year, the patient has excellent range of motion of the elbow from 0° to 150°.
jkfs-27-294-g001.jpg
Fig. 2
One case from group B. (A) Initial radiographs show AO/ASIF type C2 fracture of the distal humerus. (B) Postoperative radiographs show a bilateral locking compression plate through chevron osteotomy of olecranon. (C) At postoperative one year, the patient has excellent range of motion of the elbow from 0° to 135°.
jkfs-27-294-g002.jpg
Fig. 3
Follow-up radiographs show screw loosening of the lateral reconstruction plate in a patient with low bone mineral densities in whose operations reconstruction plates were used.
jkfs-27-294-g003.jpg
Table 1
Mayo Elbow Performance Score
jkfs-27-294-i001.jpg

Values are presented as number (%). CRP: Conventional reconstruction plate, LCP: Locking compressive plate.

Table 2
Cassebaums Classification for Elbow Range of Motion
jkfs-27-294-i002.jpg

Values are presented as number (%). ROM: Range of motion, CRP: Conventional reconstruction plate, LCP: Locking compressive plate.

Table 3
Other Clinical Results
jkfs-27-294-i003.jpg

Values are presented as median (range) or number only. CRP: Conventional reconstruction plate, LCP: Locking compressive plate, DASH: Disabilities of the arm, shoulder and hand, ROM: Range of motion.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        A Retrospective Comparative Study of Internal Fixation with Reconstruction Plate Versus Anatomical Locking Compression Plate in Displaced Intercondylar Fractures of Humerus
        J Korean Fract Soc. 2014;27(4):294-300.   Published online October 31, 2014
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      • 2
      We recommend
      Related articles
      A Retrospective Comparative Study of Internal Fixation with Reconstruction Plate Versus Anatomical Locking Compression Plate in Displaced Intercondylar Fractures of Humerus
      Image Image Image
      Fig. 1 One case from group A. (A) Initial radiographs show AO/ASIF type C2 fracture of the distal humerus. (B) Postoperative radiographs show a bilateral reconstruction plate through chevron osteotomy of olecranon. (C) At postoperative one year, the patient has excellent range of motion of the elbow from 0° to 150°.
      Fig. 2 One case from group B. (A) Initial radiographs show AO/ASIF type C2 fracture of the distal humerus. (B) Postoperative radiographs show a bilateral locking compression plate through chevron osteotomy of olecranon. (C) At postoperative one year, the patient has excellent range of motion of the elbow from 0° to 135°.
      Fig. 3 Follow-up radiographs show screw loosening of the lateral reconstruction plate in a patient with low bone mineral densities in whose operations reconstruction plates were used.
      A Retrospective Comparative Study of Internal Fixation with Reconstruction Plate Versus Anatomical Locking Compression Plate in Displaced Intercondylar Fractures of Humerus

      Mayo Elbow Performance Score

      Values are presented as number (%). CRP: Conventional reconstruction plate, LCP: Locking compressive plate.

      Cassebaums Classification for Elbow Range of Motion

      Values are presented as number (%). ROM: Range of motion, CRP: Conventional reconstruction plate, LCP: Locking compressive plate.

      Other Clinical Results

      Values are presented as median (range) or number only. CRP: Conventional reconstruction plate, LCP: Locking compressive plate, DASH: Disabilities of the arm, shoulder and hand, ROM: Range of motion.

      Table 1 Mayo Elbow Performance Score

      Values are presented as number (%). CRP: Conventional reconstruction plate, LCP: Locking compressive plate.

      Table 2 Cassebaums Classification for Elbow Range of Motion

      Values are presented as number (%). ROM: Range of motion, CRP: Conventional reconstruction plate, LCP: Locking compressive plate.

      Table 3 Other Clinical Results

      Values are presented as median (range) or number only. CRP: Conventional reconstruction plate, LCP: Locking compressive plate, DASH: Disabilities of the arm, shoulder and hand, ROM: Range of motion.


      J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
      Close layer
      TOP