Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 16(3); 2003 > Article
Original Article
Treatment of Fractures of Distal Radius using External Fixator
Sung Tae Lee, Seok Ha Lee, Kwang Jun Oh, Jong In Na, Ji Sung Jun, In Rok Yu
Journal of the Korean Society of Fractures 2003;16(3):407-415.
DOI: https://doi.org/10.12671/jksf.2003.16.3.407
Published online: June 17, 2016

Department of Orthopaedic Surgery, Konkuk University Hospital, College of Medicine, Konkuk University, Seoul, Korea.

damioh68@hotmail.com

Copyright © The Korean Fracture Society

  • 25 Views
  • 0 Download
prev next
  • PURPOSE: To assess the clinical and radiological results from the treatment of the intraarticular distal radius fracture by using the external fixator and confirm the usefulness of the external fixator from this study. MATERIALS & METHODS: We selected 20 cases of the distal radius fracture patients, who were treated with external fixator, among the patients from March, 1998 to March, 2001 and they could be followed for 1 year. There were 12 males and 8 females with a mean age of 53.4. According to AO classification, there were 2 cases for type A (10%), 2 cases for type B (10%), 5 cases for type C1 (25%), 9 cases for type C2 (45%), and 2 cases for type C3 (10%). In the 16 cases, the external fixator was used alone and in the other 2 cases, the external fixator was used with K-wires fixation. In the last 2 cases, K-wires fixation and autogenous iliac bone graft were combined. RESULTS: In more severe form of distal radius fracture such as complete intraarticular fracture (type C2, C3 of AO classification), the better outcome in clinical and radiologic results was showed when additional K-wires fixation and/or autogenous iliac bone graft were combined rather than using the external fixator only. Particularly, in the cases of type C2, the poorest outcomes of radial length loss 2.7 mm (4.0%), radial inclination loss 1.4 (4.9%), volar tilting loss 2.4 (6.9%) were showed when the external fixator was used alone. The three worst results were from the cases of using external fixator alone in type C2. In the two cases of combination with K-wire fixation, the result of type C2 was excellent and that of type C3 was good. The results of the last two cases (type C2, C3) of combination with K-wire fixation and autogenous iliac bone graft were all excellent. CONCLUSION: In this study, we confirmed that the better result could be achieved when the treatment were performed with combination with K-wire and/or autogenous iliac bone graft rather than using the external fixator alone.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Treatment of Fractures of Distal Radius using External Fixator
        J Korean Soc Fract. 2003;16(3):407-415.   Published online July 31, 2003
        Close
      • XML DownloadXML Download
      We recommend
      Related articles
      Treatment of Fractures of Distal Radius using External Fixator
      Treatment of Fractures of Distal Radius using External Fixator

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP