Most radial head fractures occur as the result of low-energy mechanisms, such as a trip or fall on the outstretched hand. These fractures typically occur when an axial load is applied to the forearm, causing the radial head to hit the capitellum of the humerus. Good results are shown with nonsurgical treatments for Mason type 2 fractures. However, if there is a limitation of elbow joint exercise or displacement of more than 2 mm, an operative treatment should be considered. We treated two patients with arthroscopic assisted bioabsorbable screw (K-METâ„¢; U&I Corporation, Uijeongbu, Korea) fixation for radial head fractures to prevent complications of open reduction and minimize radiation exposure.
Citations
Citations to this article as recorded by
Bioabsorbable Screws Used in Hallux Valgus Treatment Using Proximal Chevron Osteotomy Woo-Jin Shin, Young-Woo Chung, Ki-Yong An, Jae-Woong Seo Journal of Korean Foot and Ankle Society.2018; 22(4): 181. CrossRef
Recently, the use of intramedullary nailing for proximal femoral fractures has increased. Breakage of the nail usually occurs at the un-united fracture site, and it is a rare complication of intramedullary nailing of the femur. However, removal of the distal fragment of a broken nail is a challenging problem. Herein, the authors describe the methods used for removal of relatively fixed or strongly fixed broken intramedullary nails in two different cases.
Citations
Citations to this article as recorded by
Breakage of the Tail Portion of the Lag Screw during Removal of Proximal Femoral Zimmer Natural Nail: Report of Two Cases with Technical Notes Asep Santoso, Ik-Sun Choi, Kyung-Soon Park, Taek-Rim Yoon Hip & Pelvis.2017; 29(3): 199. CrossRef
Proximal femoral nail anti-rotation (PFNA) with a lag screw that is shaped like a spiral blade shape is an orthopedic implant to fix trochanteric fractures of the proximal femur. In addition the reason of the biomechanical advantages, PFNA widely been used recently. We report an 83-year-old man with excessive sliding of the helical blade and a femoral neck fracture after AO/OTA type A2 intertrochanteric fracture, which was fixed with a PFNA.
Citations
Citations to this article as recorded by
Helical Blade Locking Sleeve Disassembly Following Failed Femur Intertrochanter Fracture - A Case Report - Soon Ho Huh, Hong-Man Cho, Ji-Yeon Park Journal of the Korean Fracture Society.2021; 34(3): 112. CrossRef
Retrospective Comparative Study of the Intraoperative Fracture Gap Compression in the Treatment of Intertrochanteric Fracture Using Proximal Femoral Nail Antirotation Se Jin Kim, Hong Man Cho, Jiyeon Park, Ki Yong An, Young Woo Chung, Woojin Shin Journal of the Korean Fracture Society.2020; 33(4): 179. CrossRef
Failure of a Rotation Control Gamma 3 Lag Screw Used to Treat a Trochanteric Fracture Kyungho Choi, Yongtae Kim, Shicheng Zhou, Jihyo Hwang Hip & Pelvis.2018; 30(2): 129. CrossRef
Femoral neck fractures after internal fixation of trochanteric fractures with implants in situ in adults: A systematic review Antonio Barquet, Peter V. Giannoudis, Andrés Gelink Injury.2018; 49(12): 2121. CrossRef
A case of the comminuted fracture of the femoral shaft with osteoporosis is presented. The patient lacked sufficient bony stability and cortical bone-contact which allows union by conventional reconstruction method. Therefore, the authors performed a technique utilizing an intramedullary plate in combination with the standard lateral plate in order to obtain bony stabilization, early range of motion of the knee, and partial weight bearing ambulation and the technique is introduced.