-
Clinical Outcomes of Customized Staple Fixation Using K-wire in Metacarpal Base or Neck Fractures
-
Hong-ki Jin, Hyoung Min Kim, Yong Seung Oh, Jihoon Kim
-
J Korean Fract Soc 2021;34(1):23-29. Published online January 31, 2021
-
DOI: https://doi.org/10.12671/jkfs.2021.34.1.23
-
-
Abstract
PDF
- Purpose
This study was designed to evaluate the radiological and clinical outcomes of a new surgical technique—customized staple fixation using K-wire—in displaced metacarpal neck or base fractures.
Materials and Methods: From November 2016 to May 2017, 13 unstable metacarpal neck and base fractures (10 patients) were treated with II-shaped customized K-wire staples fixation, after performing open reductions through minimal dorsal incisions. The radiological and clinical outcomes were retrospectively evaluated.
Results: A mean of 2.6 staples were used for each fracture fixation. Preoperative angulation of 36.3°was reduced to 3.1° postoperatively. A week after surgery, the volar short arm splint was replaced with a dorsal splint to initiate active range of motion exercise, and the splint was subsequently removed after 3 weeks. The radiologic union was achieved at a mean of 5.1 weeks, and total active motion was recovered at a mean of 7.4 weeks. On a mean, K-wire staples were removed at 16.5 weeks after the surgery, and the mean treatment took 18.6 weeks. At the final follow-up (at mean 27.3 weeks), no significant difference was observed for total active motion of the digits and grip strength, when compared to the contralateral hand. Complete union was achieved in all fractures without deformity, or complications such as infection or nerve injury. All patients were satisfied with the cosmetic and functional outcomes.
Conclusion: K-wire stapling is an effective alternative modality in treating unstable displaced metacarpal neck or base fractures. It requires minimal incision to enable open reduction. In addition, early mobilization is ensured through the rigid fixations. Moreover, it prevents postoperative joint stiffness and reduces the time needed for treatment.
-
Citations
Citations to this article as recorded by 
- Individualized herbal prescriptions for delayed union: A case series
Jiyoon Won, Youngjin Choi, Lyang Sook Yoon, Jun-Hwan Lee, Keunsun Choi, Hyangsook Lee EXPLORE.2023; 19(2): 260. CrossRef
-
166
View
-
4
Download
-
1
Crossref
-
Does the Use of a Silicone Ring Tourniquet Help Reduce Bleeding in the Minimally Invasive Internal Fixation with Locking Plate for Distal Femoral Fractures?
-
Ki-Bong Park, Hong-Ki Jin, Il-Yeong Hwang, Sung-Who Chang, Sung-Cheon Na
-
J Korean Fract Soc 2020;33(3):148-153. Published online July 31, 2020
-
DOI: https://doi.org/10.12671/jkfs.2020.33.3.148
-
-
Abstract
PDF
- Purpose
This study evaluated the usefulness of a silicone ring tourniquet by analyzing the changes in the perioperative hemoglobin (Hb) levels or amount of perioperative bleeding compared to those of a pneumatic tourniquet or no usage during minimally invasive plate fixation for distal femoral fractures. Materials and Methods From January 2017 to December 2019, 30 patients who underwent minimally invasive plate fixation using a locking compression plate for distal femoral fractures were evaluated and classified as a silicone ring tourniquet (Group 1), a pneumatic tourniquet (Group 2), and no usage (Group 3). The variables for analysis were age, sex, preoperative Hb (preHb), postoperative 72-hour Hb (postHb), differences between preHb and postHb (preHb-postHb), amount of intraoperative and overall transfusion, estimated unit of transfusion corrected by preHb-postHb and total transfusion (Hb-lost), amount of intraoperative and postoperative and total bleeding. One-way ANOVA was used to identify the differences between the groups. Results The age, sex, operation time, preHb, preHb-postHb, amount of intraoperative and overall transfusion and Hb-lost were similar in the two groups. The amount of intraoperative bleeding was significantly lower in Group 1 than Group 3 (p=0.004), but there was no difference in the amount of postoperative and total bleeding between the two groups. Conclusion The use of a silicone ring tourniquet in the minimally invasive plate fixation for distal femoral fractures decreased the amount of intraoperative bleeding compared to no use of a tourniquet.
-
Citations
Citations to this article as recorded by 
- Silicone ring tourniquet could be a substitute for a conventional tourniquet in total knee arthroplasty with a longer surgical field: a prospective comparative study in simultaneous total knee arthroplasty
Tae sung Lee, Kwan Kyu Park, Byung Woo Cho, Woo-Suk Lee, Hyuck Min Kwon BMC Musculoskeletal Disorders.2023;[Epub] CrossRef
-
257
View
-
0
Download
-
1
Crossref
|