Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Articles

Page Path
HOME > J Musculoskelet Trauma > Volume 18(2); 2005 > Article
Original Article
Treatment of Failed Internal Fixation of Intertrochanteric Fractures of Femur
Hyung Gyu Kim, Byeong Mun Park, Kyeong Seop Song, Chang Hun Sung, Jong Min Kim, Jae Hyung Cho, Nam Heun Kim
Journal of the Korean Fracture Society 2005;18(2):120-125.
DOI: https://doi.org/10.12671/jkfs.2005.18.2.120
Published online: June 16, 2016

Department of Orthopedic Surgery, Kwang Myung Sung-ae General Hospital, Seoul, Korea.

SKSUB@Hotmail.com

Copyright © The Korean Fracture Society. All rights reserved

  • 491 Views
  • 1 Download
  • 1 Crossref
prev next
  • PURPOSE: To compare the result of failed internal fixation of intertrochanteric fractures treated with arthroplasty and 95degrees angled blade plate. MATERIALS AND METHODS: From June 2000 to may 2003, there were 12 cases with failed internal fixation of intertrochanteric fractures among 185 cases treated with dynamic hip screw and followed up for more than 1 year. The 4 cases were treated with bipolar hemiarthroplasty, 1 case with total hip arthroplasty, and other 7 cases were treated with 95degrees angled blade plate with allograft, evaluated clinically the operation times, blood loss, walking ability and complication. RESULTS: In the 7 cases, which treated with 95degrees angled blade plate, the average operation time was 109 minutes, the average blood loss was 431 ml. The result of keeping abreast of 1 year, no aid ambulation was 4 cases, the cane ambulation was 2 cases, the walker ambulation was 1 case, and there was no pain in 3 cases, mild pain in 4 cases, and no moderate pain. In the 5 cases, which treated with arthroplasty, the average operation time was 157 minutes, the average blood loss was 618 ml. During 1 year, no aid ambulation was 3 cases, the cane ambulation was 1 case, the walker ambulation was 1 case, and no pain in 2 cases, mild pain in 1 case, moderate pain in 1 case. CONCLUSION: Both 95degrees angled blade plate and arthroplasty can be useful for failed internal fixation of intertrochanteric fractures, and the choice of implant must be determined with caution, considering the surgical conditions of patient, as well as benefits of each devices

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  
    • Complication Analysis of Conversion Hip Arthroplasty after Failed Intertrochanteric Fracture Fixation: A Meta-Analysis
      Naye Kang, Ki-Tae Park, Suyeon Park, Eunseo Joung, Nah Yon Kim, Byung-Ho Yoon
      Clinics in Orthopedic Surgery.2026; 18(2): 228.     CrossRef

    • Cite
      CITE
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Treatment of Failed Internal Fixation of Intertrochanteric Fractures of Femur
      J Korean Fract Soc. 2005;18(2):120-125.   Published online April 30, 2005
      Close
    • XML DownloadXML Download
    We recommend
    Related articles
    Treatment of Failed Internal Fixation of Intertrochanteric Fractures of Femur
    Treatment of Failed Internal Fixation of Intertrochanteric Fractures of Femur

    J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
    Close layer
    TOP