Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Articles

Page Path
HOME > J Musculoskelet Trauma > Volume 19(4); 2006 > Article
Original Article
The Treatement of the Unstable Proximal Humerus Fracture Using Bifurcate Angled Blade Plate with Tension Band Wiring
Kuen Tak Suh, Hyoung Lok Roh, Myung Soo Youn, Jung Sub Lee
Journal of the Korean Fracture Society 2006;19(4):424-430.
DOI: https://doi.org/10.12671/jkfs.2006.19.4.424
Published online: June 16, 2016

Department of Orthopaedic Surgery, Pusan National University School of Medicine, Busan, Korea.

jungsublee@pusan.ac.kr

Copyright © The Korean Fracture Society. All rights reserved

  • 113 Views
  • 0 Download
  • 1 Crossref
prev next
  • PURPOSE: To evaluate the results of internal fixation with bifurcate angled blade plate and tension band wiring of greater tuberosity or rotator cuff for the unstable proximal humerus fracture. MATERIALS AND METHODS: Nineteen cases of unstable proximal humerus fracture who were followed up for more than 1 year were treated using bifurcate angled blade plate and tension band wiring between March 2003 and March 2005. Average age of the patients was 46.5 years (range, 24 to 69), and there were 9 male and 10 female patients. The radiological results were evaluated by bony union and neck shaft angle. In addition, the clinical results were evaluated by Neer's evaluation criteria. RESULTS: In 18 out of 19 cases, bony union was obtained in average 12.5 weeks after operation. The neck shaft angles of sixteen cases were between 120 and 140 degrees by Paavolainen method. According to Neer's evaluation criteria, 17 cases showed excellent or good results. CONCLUSION: The patients treated using bifurcate angled blade plate and tension band wiring could exercise earlier because of good initial stability. Also, the radiological and clinical results were relatively good. The treatment of unstable proximal humerus fracture with bifurcate angled blade plate and tension band wiring was considered as a good method.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  
    • Hemiarthoplasty with Bone Block Graft and Low Profile Prosthesis for the Comminuted Proximal Humerus Fractures
      Chung Hee Oh, Joo Han Oh, Sae Hoon Kim, Ki Hyun Jo, Sung Woo Bin, Hyun Sik Gong
      Journal of the Korean Fracture Society.2008; 21(3): 213.     CrossRef

    • Cite
      CITE
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      The Treatement of the Unstable Proximal Humerus Fracture Using Bifurcate Angled Blade Plate with Tension Band Wiring
      J Korean Fract Soc. 2006;19(4):424-430.   Published online October 31, 2006
      Close
    • XML DownloadXML Download
    We recommend
    The Treatement of the Unstable Proximal Humerus Fracture Using Bifurcate Angled Blade Plate with Tension Band Wiring
    The Treatement of the Unstable Proximal Humerus Fracture Using Bifurcate Angled Blade Plate with Tension Band Wiring

    J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
    Close layer
    TOP