Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 17(4); 2004 > Article
Original Article
Correlation between Anterior and Posterior Obliquity of the Sliding Lag Screw and Stability in Unstable Intertrochanteric Fractures
Kyu Hyun Yang, Je Hyun Yoo, Dong Joo Rhee, Jung Hoon Won, Dae Ya Kim, Dong Sik Sim
Journal of the Korean Fracture Society 2004;17(4):308-313.
DOI: https://doi.org/10.12671/jkfs.2004.17.4.308
Published online: June 17, 2016

Department of Orthopaedic Surgery, Yongdong Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.

kyang@yumc.yonsei.ac.kr

Copyright © The Korean Fracture Society. All rights reserved

  • 29 Views
  • 0 Download
prev next
  • PURPOSE: To investigate the characteristics of the sliding pattern of the proximal fragment (head and neck) in unstable intertrochanteric fractures, which were fixed with a dynamic hip screw (DHS) with anterior to posterior or posterior to anterior insertion angle in the axial view. MATERIALS AND METHODS: AO type A2.1 intertrochanteric fracture was reproduced in 10 proximal femur model (Synbone, Malans, Switzerland). Five fractured models were reduced and fixed using DHS with anterior to posterior insertion angle (group 1) and five models were fixed with posterior to anterior angle (group 2). Load of 500 N (30 cycles) was applied to the fracture fragment-plate complex using Instron 6022. Data on the distance of sliding and the angle of rotation of the proximal fragment were collected and analyzed. RESULTS: No significant difference was noted statistically in the distance of sliding between the two groups (p=0.92). However, the mean angle of rotation was 13.4degrees and 8.0degrees in group 1 and 2, respectively and the difference was statistically significant (p=0.012). Anterior cortical fracture of distal fragment was noted in 3 cases of group 1. There was no fracture of the anterior cortex in group 2. CONCLUSION: In unstable intertrochanteric fracture, the insertion angle of the lag screw in axial view does seem to play a role in the fate of bone-plate complex. Early eccentric contact of both fragments caused rotation of the proximal fragment in all cases and anterior cortical fracture of the distal fragment in 3 cases of group 1.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Correlation between Anterior and Posterior Obliquity of the Sliding Lag Screw and Stability in Unstable Intertrochanteric Fractures
        J Korean Fract Soc. 2004;17(4):308-313.   Published online October 31, 2004
        Close
      • XML DownloadXML Download
      We recommend
      Correlation between Anterior and Posterior Obliquity of the Sliding Lag Screw and Stability in Unstable Intertrochanteric Fractures
      Correlation between Anterior and Posterior Obliquity of the Sliding Lag Screw and Stability in Unstable Intertrochanteric Fractures

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP