Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 3(2); 1990 > Article
Original Article
Supracondylar-Intercondylar Fracture of the Femur Treatment by Internal Fixation Using May Anatomical Contouring Plate
Sung Joon Kim, Jae Lim Cho, Hyun Kee Chung, Sung Ju Lee
Journal of the Korean Society of Fractures 1990;3(2):180-188.
DOI: https://doi.org/10.12671/jksf.1990.3.2.180
Published online: July 14, 2016

Department of Orthopaedics Surgery, Hanyang University College, Seoul, Korea.

Copyright © The Korean Fracture Society

  • 90 Views
  • 0 Download
prev next
  • Between Jan. 1988 and Dec. 1989, 15 supracondylar-intercondylar fractures of the femur were treated in the department of orthopaedic surgery, Hanyang University, College of medicine.
    The advantages of the May Anatomical contouring plate are:
    1. The device is self-reducting, so the reduction of the fracture was easy.
    2. The device facilitates good condylar fixation even in the osteoportic bone of the elderly patients without destruction of the fragment.
    3. Distal end of the jplate is not heavy, so any problem of the soft tissue was not encountered.
    4. A small amount of equipment and procedure was required, so the time of operation could be shortened.
    The results were as follows:
    1. Seven patients were male and four patients were femal.
    2. The fracture was caused by a motor-vehicle accident in eight cases, a fall in two cases, and slip down in two cases.
    3. There were one I, two II, two II, eight III fractures according to Neer classification.
    4. The method of treatment was open reduction and figid iinternal fixation using May anatomical contouring plate.
    5. 50% fo good to excellent results were obtained according to Neer rating system.
    6. Complications included delayed union(1 case) and metal failure(1 case).

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Supracondylar-Intercondylar Fracture of the Femur Treatment by Internal Fixation Using May Anatomical Contouring Plate
        J Korean Soc Fract. 1990;3(2):180-188.   Published online November 30, 1990
        Close
      • XML DownloadXML Download
      We recommend
      Supracondylar-Intercondylar Fracture of the Femur Treatment by Internal Fixation Using May Anatomical Contouring Plate
      Supracondylar-Intercondylar Fracture of the Femur Treatment by Internal Fixation Using May Anatomical Contouring Plate

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP