Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 14(4); 2001 > Article
Original Article
Treatment of unstable pertrochanteric fracture of the femur using compression hip screw and plate with 6 or more holes
Jeong-Woung Lee, Chi-Weon Lee, Doo-Hoon Sun, Myung-Sang Moon
Journal of the Korean Society of Fractures 2001;14(4):592-600.
DOI: https://doi.org/10.12671/jksf.2001.14.4.592
Published online: July 1, 2016

Copyright © The Korean Fracture Society

  • 87 Views
  • 0 Download
prev next
  • Purpose
    The objectives of this study are to observe and report the clinical results of the treatment of unstable pertrochanteric femur fracture extending into subtrochanter or shaft of the femur using compression hip screw and plate with 6 or more holes.
  • Materials and Methods
    Between February 1993 and December 1997, 39 patients were treated surgically for unstable pertrochanteric femur fracture. 26 patients who have been followed up over twelve months were included in this study. Surgery was performed within 2 weeks after injury, except one patient who had combined head injury. The fracture was fixed internally with compression hip screw and plate with 6 or more holes, and additional fixations were also performed with Cable wire, interfragmentary screw and Knowles pin.
    The result was analyzed radiographically and clinically for blood loss, surgery time, bony union period and complication.
    Average estimated blood loss was 910 cc. Average surgery time was one hundred ten minutes. The complications occurred in 7 cases (27%) ; 1 nonunion, 2 screw loosening and 4 cases of superficial wound infection.
    There was no case of lag screw penetration to the femoral head or metal failure.
    The bony union was obtained at average 22 weeks.
  • Conclusion
    With use of the compression hip screw and long plate with 6 or more holes for stable internal fixation, we obtained satisfactory results for unstable pertrochanteric femur fracture extending into subtrochanter or shaft of the femur.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Treatment of unstable pertrochanteric fracture of the femur using compression hip screw and plate with 6 or more holes
        J Korean Soc Fract. 2001;14(4):592-600.   Published online October 31, 2001
        Close
      • XML DownloadXML Download
      We recommend
      Treatment of unstable pertrochanteric fracture of the femur using compression hip screw and plate with 6 or more holes
      Treatment of unstable pertrochanteric fracture of the femur using compression hip screw and plate with 6 or more holes

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP