Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 15(2); 2002 > Article
Original Article
Treatment of Comminuted Trochanteric Fracture with Dynamic Hip Screw and Trochanteric Stabilizing Plate
Seungki Baek, Youngjoon Choi, Chunghwan Kim, Yoojin Kim, Jaekwang Hwang, Hyungsun Ahn, Hyuntae Ahn, Kyungjun Park, Jaiwoo Cho
Journal of the Korean Society of Fractures 2002;15(2):278-285.
DOI: https://doi.org/10.12671/jksf.2002.15.2.278
Published online: June 21, 2016

Department of Orthopedic Surgery, Kangnung hospital, ulsan university, kangnung, Korea.

SKBAEK@knh.co.kr

Copyright © The Korean Fracture Society

  • 114 Views
  • 0 Download
  • 2 Crossref
prev next
  • PURPOSE: The purpose of this study is to evaluate the results of treatment of comminuted femoral trochanteric fracture using dynamic hip screw(DHS) with trochanteric stabilizing plate(TSP) and DHS only. MATERIALS AND METHODS: we analysed retrospectively 32 cases that has fracture extends over two or more levels of medial cortex(A2 of AO classification) and fracture extends through lateral cortex of femur(A3 of AO classicification) of femoral trochanteric fractures between 1997 and 2000. On simple AP radiograph of the DHS with TSP(n=16) and DHS only group(n=16), we reviewed bony union, slippage of lag screw, lateral displacement of greater trochanter. RESULT: Bony union was observed in all cases. When bony union is done in follow up radiograph, Mean slippage of lag screw is 14.5mm in DHS only group, 12.6mm in DHS with TSP group and mean lateral displacement of greater trochanter is 9.8mm in DHS only group, 1.2mm in DHS with TSP group. CONCLUSION: Use of DHS with TSP in comminuted femoral trochanteric fracture is lesser slippage of lag screw and lateral displacement of greater trochanter than DHS only used, and that is better method to maintain fracture reduction and internal fixation in treatment of comminuted femoral trochanteric fractures than DHS only.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  
    • Results of Use of Compression Hip Screw with Trochanter Stabilizing Plate for Reverse Oblique Intertrochanteric Fracture
      Byung-Woo Min, Kyung-Jae Lee, Gyo-Wook Kim, Ki-Cheor Bae, Si-Wook Lee, Du-Han Kim
      Journal of the Korean Fracture Society.2014; 27(2): 120.     CrossRef
    • A Comparison of Intramedullary and Extramedullary Fixations for the Treatment of Reverse Oblique or Transverse Intertrochanteric Femoral Fractures
      Yerl-Bo Sung, Jung-Yun Choi, Eui-Yub Jung
      Hip & Pelvis.2012; 24(2): 109.     CrossRef

    • Cite
      CITE
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Treatment of Comminuted Trochanteric Fracture with Dynamic Hip Screw and Trochanteric Stabilizing Plate
      J Korean Soc Fract. 2002;15(2):278-285.   Published online April 30, 2002
      Close
    • XML DownloadXML Download
    We recommend
    Treatment of Comminuted Trochanteric Fracture with Dynamic Hip Screw and Trochanteric Stabilizing Plate
    Treatment of Comminuted Trochanteric Fracture with Dynamic Hip Screw and Trochanteric Stabilizing Plate

    J Korean Soc Fract : Journal of the Korean Society of Fractures
    Close layer
    TOP