Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 11(3); 1998 > Article
Original Article
Nonunions of the Humeral Shaft Fracture after treating by the Seidel Humeral Locking Nail
Young Bae Pyo, Kong Min Shin, Pyong Ju
Journal of the Korean Society of Fractures 1998;11(3):690-695.
DOI: https://doi.org/10.12671/jksf.1998.11.3.690
Published online: June 23, 2016

Department of Orthopaedic Surgery, Clooege of Medicine, Chosun University, Korea.

Copyright © The Korean Fracture Society

  • 91 Views
  • 0 Download
prev next
  • The authors analyzed 34 cases of humeral shaft fractures in patients who were treated by the Seidel intramedullary nailing from March 1994 to August 1996. Average follow-up period was 18 months(12 months - 26 months). We experienced nonunions of 5 cases(14.7%). The nonunions were found mostly at the comminuted midshaft fractures. The probable cause of nonunion was distraction of fracture ends due to intramedullary endosteal lysis and failure of fanning within postoperative 3 months. These 4 cases of nonunion were treated with rigin internal fixation and additional bone graft, and 1 case with refanning only. So we concluded that the eidel system ws insufficient fixation technique because of the distal spreading-fin loosening. Distal screw-locked nailing seemed to be nn more useful technique unless there are major modifications to the Seidel nail itself.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Nonunions of the Humeral Shaft Fracture after treating by the Seidel Humeral Locking Nail
        J Korean Soc Fract. 1998;11(3):690-695.   Published online July 31, 1998
        Close
      • XML DownloadXML Download
      We recommend
      Nonunions of the Humeral Shaft Fracture after treating by the Seidel Humeral Locking Nail
      Nonunions of the Humeral Shaft Fracture after treating by the Seidel Humeral Locking Nail

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP