Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 8(2); 1995 > Article
Original Article
A Clinical Analysis on Treatment of Tibial Fractures Using Ex-Fi-Re External Fixator
Soo-Kyun Rah, Dae-Ik Kim, Chang-Uk Choi
Journal of the Korean Society of Fractures 1995;8(2):354-360.
DOI: https://doi.org/10.12671/jksf.1995.8.2.354
Published online: July 8, 2016

Department of Orthopaedic Surgery, College of Medicine, Soonchunhyang University, Seoul, Korea.

Copyright © The Korean Fracture Society

  • 42 Views
  • 0 Download
prev next
  • Since Malgaigne described a external fixators in 1853, it were widely used for open and communited fractures. Modern external fixators such as modified Hoffman, Denham and of hofix external fixators are commonly applied because it could obtain rigid fixation and compression of fracture site.
    Most of external fixators used only as a fixator after reduction, however new extemal fixator(Ex-F-Re) by Osteo is consists of two units, which are the correction and fixation units. This device is possible to manipulate fracture fragments under the complete control of stability and to obtain more rigid fixation and compression of fracture site.
    Among the 16 cases of tibial fractures treated with Ex-Fi-Re external fixator device from June 1992 to June 1993, 14 casrs had minimum 1 year follow up and the following results were obtained.
    1. Among 14 cases,7 were open fractures,4 were closed periarticular communited fractures and 3 were infected nonunion of tibia.
    2. Among 11 cases of fracture and 3 cases of infected nonunion, nonunion was happened in each one case.
    3. Average bony union period was 24.4 weeks in fracture group and 44 weeks in infected nonunion group.
    4. Ex-Fi-Re external fixator was very rigid fixator, easy to use, and possible to manipulate fracture fragments under the complete control of stability.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        A Clinical Analysis on Treatment of Tibial Fractures Using Ex-Fi-Re External Fixator
        J Korean Soc Fract. 1995;8(2):354-360.   Published online April 30, 1995
        Close
      • XML DownloadXML Download
      We recommend
      A Clinical Analysis on Treatment of Tibial Fractures Using Ex-Fi-Re External Fixator
      A Clinical Analysis on Treatment of Tibial Fractures Using Ex-Fi-Re External Fixator

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP