Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 7(2); 1994 > Article
Original Article
Operative Treatment with Plate Screw Devices for Distal Femoral Fracture
Hak Yeong Jeong, Seung Wook Yang, Young Cheol Shin, Han Sung Park
Journal of the Korean Society of Fractures 1994;7(2):512-521.
DOI: https://doi.org/10.12671/jksf.1994.7.2.512
Published online: July 13, 2016

Department of Orthopaedic surgery, Maryknoll Hospital, Pusan, Korea.

Copyright © The Korean Fracture Society

  • 39 Views
  • 0 Download
prev next
  • Until 1960, conservative managemant was considered superior to operative treatment of distal femoral fracture. But with advancement of new fixation divices and techniques, open reduction and internal fixation is recent trend.
    From May, 1986, to May, 1993, at Pusan Maryknoll hospital, the results of 39 cases of distal femoral fracture treated operatively with plate screw devices were analyzed after minimum follow up of 1 year according to the rating system of Schatzker and lambert.
    The results were as follows:
    1. Average radiologic union time was 16.3 weeks.
    2. According to Schatzker and Lamberts criteria, excellent was 17 cases, good in 13 cases, fair in 5 cases and failure in 4 cases.
    3. For fixation of distal femoral fracture with severe comminution at metaphyseal portion, the condylar blade plate and dynamic condylar screw showed better result than anatomical plate.
    4. With extensile approach, the dynamic condylar screw showed excellent result for distal femoral fracture with intraarticular comminution.
    We concluded that wide exposure enough for accurate reduction of fracture fragments aud joint surface and rigid internal fixation were the cornerstone for treatment of the distal femoral fracture.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Operative Treatment with Plate Screw Devices for Distal Femoral Fracture
        J Korean Soc Fract. 1994;7(2):512-521.   Published online November 30, 1994
        Close
      • XML DownloadXML Download
      We recommend
      Operative Treatment with Plate Screw Devices for Distal Femoral Fracture
      Operative Treatment with Plate Screw Devices for Distal Femoral Fracture

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP