Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 17(4); 2004 > Article
Original Article
Evaluation of Osseointegration in Titanium Alloy Cortical Screws with the Passage of Time
Jae Hyup Lee, Bong Soon Chang, Choon Ki Lee
Journal of the Korean Fracture Society 2004;17(4):401-407.
DOI: https://doi.org/10.12671/jkfs.2004.17.4.401
Published online: June 17, 2016

Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea.

Department of Orthopedic Surgery, Gachon Medical School, Incheon, Korea.

choonki@plaza.snu.ac.kr

Copyright © The Korean Fracture Society. All rights reserved

  • 78 Views
  • 0 Download
prev
  • PURPOSE: To evaluate the osseointegration of titanium alloy cortical screws with the passage of time. MATERIALS AND METHODS: Fifty four titanium alloy cortical screws (24 mm in length, 3.5 mm in diameter) were implanted bilaterally in the tibial diaphysis of adult mongrel male dogs of similar size and weight (30 ±5 kg). The insertion torques, radiographs, undecalcified histology, histomorphometric analysis and extraction torques were evaluated at 2, 4 and 8 weeks after surgery. RESULTS: The extraction torque at 2 weeks (1.14±0.470 cN. m) was significantly lower than the insertion torque (1.76±0.609 cN. m) (p=0.0071), the extraction torque at 4 weeks (2.57±1.36 cN. m) was slightly improved and the extraction torque at 8 weeks (3.18±0.499 cN. m) was significantly higher than insertion torque (p=0.0005). Direct bony contact in the early phase was poor and intervening fibrous tissue was observed at the bone-screw interface. However, the fixation between the bone and the screws improved with time. The percentage of bone-screw contact at 8 weeks (33.1±18.5%) was higher than that of 2 weeks (22.4±12.9%), but not statistically significant. CONCLUSION: Because of thermal injury or pressure necrosis, the fixation strength of titanium alloy cortical screws at 2 weeks after implantation is significantly lower than that at the insertion time. So, we should keep in mind the initial phase weakness of screw fixation when we allow the patients the range of motion exercise or weight bearing and the improvement of the initial phase fixation is very important in clinical results.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Evaluation of Osseointegration in Titanium Alloy Cortical Screws with the Passage of Time
        J Korean Fract Soc. 2004;17(4):401-407.   Published online October 31, 2004
        Close
      • XML DownloadXML Download
      We recommend
      Evaluation of Osseointegration in Titanium Alloy Cortical Screws with the Passage of Time
      Evaluation of Osseointegration in Titanium Alloy Cortical Screws with the Passage of Time

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP