  • PURPOSE: The purpose of this study is to analyze the result and complications of treatment using percutaneous K-wire stabilization for fractures of the proximal humerus. MATERIALS & METHOD: To be eligible for the study, total 12 patients of displaced two, three or four part fractures of the proximal humerus were treated, 10 females and 2 males with a mean age of 52 years (range 18-76 year). Reduction was obtained by longitudinal traction combined with posterior pressure on the humeral shaft. After reduction, minimum two 2.5mm terminal threaded pin or smooth tip K-wire was inserted. RESULTS: Union rate of 83.3% was observed at an average 2.7 months. Range of motion of shoulder was 125 degrees of forward flexion, 114 degrees of abduction. Patients of 83.3% had good or excellent functional result. Four patients had a mild, superficial pin tract infection associated with loosening of the pin. The infections resolved with removal of pin and oral antibiotics. Valgus deformity was developed in a patient however the patient subsequently had a good functional result and nonunion were developed in two cases. CONCLUSION: The technique of closed reduction and percutaneous pinning is quite demanding procedure, although it may appear to be deceptively simples. The good indications for the use of this procedure seems to patients with severe comminuted fractures, old age with osteoporosis. For the more rigid fixation, terminally threaded pins should be used, not smooth pin.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Closed percutaneous K-wire stabilization for fractures of the proximal humerus
        J Korean Soc Fract. 2002;15(4):566-572.   Published online October 31, 2002
        Close
      • XML DownloadXML Download
      We recommend
      Closed percutaneous K-wire stabilization for fractures of the proximal humerus
      Closed percutaneous K-wire stabilization for fractures of the proximal humerus

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP