The Usefulness of Low-Intensity Ultrasound for Nonunion and Delayed Union
Yeo Heon Yun, Jong Oh Kim, Young Do Ko, Jae Doo Yoo, Jun Mo Jung, Jong Gun Oh, Han Chen Bang, Chang Ho Choi, Myeung cheol Shin
Journal of the Korean Society of Fractures 2003;16(1):104-111.
DOI: https://doi.org/10.12671/jksf.2003.16.1.104
Published online: June 17, 2016

Department of Orthopedic Surgery, College of Medicine, Ewha womans University, Mok-Dong Hospital Seoul, Korea.

yhyun@mm.ewha.ac.kr

Copyright © The Korean Fracture Society

  • 75 Views
  • 0 Download
prev next
  • PURPOSE: To evaluation of usefulness of low-intensity ultrasound for nonunion and delayed union. MATERIALS AND METHODS: For 5 months, we treated 7 delayed union and 8 nonunion using low-intensity ultrasound. After 5 months, in checked X-ray AP and Lateral view, when cortical bridge formation was done, we through union. RESULTS: In 7 delayed union, 5 cases-2 femur, tibia, humerus, radius were healed. In 8 nonunion, 3 femur nonunion were healed. Union rate was 71% in delayed union 37.5% in nonunion. CONCLUSION: we thought that the low-intensity ultrasound has capacity of induction of union and was considered as the method of treatment for delayed union.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        The Usefulness of Low-Intensity Ultrasound for Nonunion and Delayed Union
        J Korean Soc Fract. 2003;16(1):104-111.   Published online January 31, 2003
        Close
      • XML DownloadXML Download
      We recommend
      The Usefulness of Low-Intensity Ultrasound for Nonunion and Delayed Union
      The Usefulness of Low-Intensity Ultrasound for Nonunion and Delayed Union

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP