Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 14(1); 2001 > Article
Original Article
The Neccessity of Additional Supporting Fixation for the Unstable Intertrochanteric Fractures of the Femur in the Elderly
Hyoun Oh Cho, Kyoung Duck Kwak, Soo Min Sohn, Cheol Ho Kang, Seung Il Whang, Sang Min An, Do Young Lee
Journal of the Korean Society of Fractures 2001;14(1):23-29.
DOI: https://doi.org/10.12671/jksf.2001.14.1.23
Published online: July 1, 2016

Copyright © The Korean Fracture Society

  • 52 Views
  • 0 Download
prev next
  • Purpose
    This study was designed to assess the necessity of additional supporting fixation to the traditional internal fixation for unstable intertrochanteric fractures of femur.
  • Materials and Methods
    Seventy two cases of unstable intertrochanteric fractures (modified Boyd-Anderson type III, IV) in the elderly were reviewed, which were internally fixed with Dynamic Hip Screw. 48 cases were treated with Dynamic Hip Screw only(Group I) and 24 cases with Dynamic Hip Screw and additional trochanteric supporting plate(Group II). In 13 cases with weak femoral cortx, we added wiring to the side plate. We measured neck-shaft angle, degrees of displacement of greater trochanteric fragment, slippage of hip screw on plain radiographs.
  • Results
    Varus change in neck-shaft angle, displacement of greater trochanteric fragment and slippage of hip screw revealed 7.3°, 5.4 mm, and 10.7 mm respectively in group I, while 2.1°, 0.1 mm and 3.8 mm respectively in group II. There were no pullout of cortical screws.
  • Conclusion
    Internal fixation with additional trochanteric supporting plate to the conventional Dynamic Hip Screw was effective in unstable intertrochanteric fractures of the femur in the elderly. Added wiring to the side plate was also helpful in weak femoral cortex.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        The Neccessity of Additional Supporting Fixation for the Unstable Intertrochanteric Fractures of the Femur in the Elderly
        J Korean Soc Fract. 2001;14(1):23-29.   Published online January 31, 2001
        Close
      • XML DownloadXML Download
      We recommend
      The Neccessity of Additional Supporting Fixation for the Unstable Intertrochanteric Fractures of the Femur in the Elderly
      The Neccessity of Additional Supporting Fixation for the Unstable Intertrochanteric Fractures of the Femur in the Elderly

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP