T-Plate Fixation for Two- and Three-Part Fractures of the Proximal Humerus
Dong Ju Shin, Se Ang Chang, Young Soo Byun, Dae Hee Hwang, Sung Rak Lee, Sang Hee Kim
Journal of the Korean Fracture Society 2005;18(4):426-431.
DOI: https://doi.org/10.12671/jkfs.2005.18.4.426
Published online: June 16, 2016

Department of Orthopaedic Surgery, Daegu Fatima Hospital, Daegu, Korea.

fatimaos@unitel.co.kr

Copyright © The Korean Fracture Society. All rights reserved

  • 32 Views
  • 0 Download
  • 1 Crossref
prev next
  • PURPOSE: To evaluate the results and complications of treatment using T-plate fixation for two- and three-part fractures of the proximal humerus. MATERIALS AND METHODS: Between January 1996 and July 2003, thirty-three patients with two-part and three-part fractures of the proximal humerus were treated by T-plate fixation. There were 21 two-part fractures and 12 three-part fractures including three shoulder dislocations. The reduction was qualified and complications were assessed with final radiographs. The functional outcome was evaluated by Neer's rating system. RESULTS: Thirty-two cases (96.7%) were united, twenty-nine cases (87.9%) were reduced as good, and twenty-three cases (70%) had excellent or satisfactory results. There were four cases of loss of reduction, three cases of stiff joint, one case of nonunion, and one case of avascular necrosis of the humeral head, but no infection. No correlation was found between the final result and the type of fracture, age, gender, or quality of reduction. CONCLUSION: T-plate fixation for proximal humeral fractures is a reliable method to obtain good results through satisfactory reduction, rigid fixation, and early movement. Additional tension band wiring can provide stable fixation for osteoporotic or comminuted fractures difficult to obtain stable fixation.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  
    • The Surgical Outcomes for Isolated Greater Tuberosity Fracture of Proximal Humerus
      Eun-Sun Moon, Myung-Sun Kim, Young-Jin Kim
      Journal of the Korean Fracture Society.2007; 20(3): 239.     CrossRef

    • Cite
      CITE
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      T-Plate Fixation for Two- and Three-Part Fractures of the Proximal Humerus
      J Korean Fract Soc. 2005;18(4):426-431.   Published online October 31, 2005
      Close
    • XML DownloadXML Download
    We recommend
    T-Plate Fixation for Two- and Three-Part Fractures of the Proximal Humerus
    T-Plate Fixation for Two- and Three-Part Fractures of the Proximal Humerus

    J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
    Close layer
    TOP