Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 15(3); 2002 > Article
Original Article
Treatment of the Distal Metaphyseal Fractures of Tibia - Comparison between Internal Fixation with a Plate and screws and External Fixation with Ilizarov Device
Sung Churl Lee, Moon Jib Yoo, Hyun Seok Seo
Journal of the Korean Society of Fractures 2002;15(3):371-378.
DOI: https://doi.org/10.12671/jksf.2002.15.3.371
Published online: June 17, 2016

Department of Orthopaedic Surgery Dankook University College of Medicine, Chonan, Korea.

doctorQ@anseo.dankook.ac.kr

Copyright © The Korean Fracture Society

  • 110 Views
  • 0 Download
  • 1 Crossref
prev next
  • PURPOSE: The purpose of this study was to compare the results between open reduction and internal fixation with plate and screws and closed reduction and external fixation with Ilizarov device for the fracture of disatal metaphyseal fracture of tibia. MATERIALS AND METHODS: In this study, the results in treatment of the 19 distal metaphyseal fractures of tibia with closed reduction and external fixation with Ilizarov device were compared with those in treatment of the 23 fractures with open reduction and internal fixation with a plate and screws. The cases were the patients who had been treated for the fractures at the Department of Orthopaedic Surgery, Dankook University Hospital from May 1997 to December 2000. The results of treatment were analysed using functional evaluation by Mast and Teipner and radiological evaluation by Ovadia and Beals. RESULTS: The results were as follows: 1. The major causes of injury were motor vehecle accidents, fall-downs, and falls from a height in order. 2. Treatment of the fractures with closed reduction and external fixation with Ilizarov device showed comparable results to that with open reduction and internal fixation with a plate and screws. 3. Complications in treatment were a little more frequent in open reduction and internal fixation with a plate and screws than in closed reduction and external fixation with Ilizarov device. CONCLUSION: Considering the results, closed reduction and external fixation with Ilizarov device is thought to be one of recommendable options in treatment of the distal metaphyseal fractures of tibia with the advantages in wound management, prevention of stiffness of ankle joint, and convenience in removal of the device.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  
    • Mid-term Results of Distal Tibial Fractures Treated with Ilizarov External Fixator
      Suk Kyu Choo, Kyung Wook Nha, Hyoung Keun Oh, Dong Bong Lee
      Journal of the Korean Fracture Society.2007; 20(4): 323.     CrossRef

    • Cite
      CITE
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Treatment of the Distal Metaphyseal Fractures of Tibia - Comparison between Internal Fixation with a Plate and screws and External Fixation with Ilizarov Device
      J Korean Soc Fract. 2002;15(3):371-378.   Published online July 31, 2002
      Close
    • XML DownloadXML Download
    We recommend
    Treatment of the Distal Metaphyseal Fractures of Tibia - Comparison between Internal Fixation with a Plate and screws and External Fixation with Ilizarov Device
    Treatment of the Distal Metaphyseal Fractures of Tibia - Comparison between Internal Fixation with a Plate and screws and External Fixation with Ilizarov Device

    J Korean Soc Fract : Journal of the Korean Society of Fractures
    Close layer
    TOP