The Biomechanics of Hybrid External Fixator: The Effect of Periarticular Half Pin on Frame Stiffness
Jong Keon Oh, Duk Young Jung, In Su Kim
Journal of the Korean Society of Fractures 2002;15(2):114-122.
DOI: https://doi.org/10.12671/jksf.2002.15.2.114
Published online: June 21, 2016

Department of Orthopedic Surgery, College of Medicine, Ewha Womans University, Seoul, Korea.

Institute for Frontier Medical Sciences, Kyoto University, Kyoto, Japan.

jongkeon@mm.ewha.ac.kr

Copyright © The Korean Fracture Society

  • 95 Views
  • 1 Download
prev next
  • OBJECTIVES: The purpose of this study was to identify the biomechanical effect of periarticular half pin in the hybrid external fixator. METHODS: Simulated tibial plateau fractures were created using a polyvinylchloride pipe. Seven frame configurations were tested : a four-ring Ilizarov frame, a hybrid frame with three wires on peri-articular fragment, hybrid frames with wires and half pins on peri-articular fragment by four different configurations, a hybrid frame constructed with multiple levels of fixation in the periarticular fragment. A materials testing machine was used to apply pure compression, anterior and posterior bending, medial and lateral bending, and torsion. Stiffness values were calculated from the load deformation and torque angle curves RESULTS: The overall stiffness of the hybrid frame was increased up to 30% by replacing a coronal tension wire with a half pin placed on the sagittal plane. The hybrid frame constructed with two wires and a half pin on the sagittal plane of the periarticular fragment showed overall stiffness compatible with that of multi-level peri-articular fixation frame. CONCLUSION: Our results show that the half pin placed on the periarticular fragment can be a effective tool to increase the stiffness of hybrid external fixators in this periarticular tibia fracture model.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        The Biomechanics of Hybrid External Fixator: The Effect of Periarticular Half Pin on Frame Stiffness
        J Korean Soc Fract. 2002;15(2):114-122.   Published online April 30, 2002
        Close
      • XML DownloadXML Download
      We recommend
      The Biomechanics of Hybrid External Fixator: The Effect of Periarticular Half Pin on Frame Stiffness
      The Biomechanics of Hybrid External Fixator: The Effect of Periarticular Half Pin on Frame Stiffness

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP