Segmental Breakage of Distal Interlocking Screw Complicating removal of broken nail: A Case Report
Kyu Hyun Yang, Seong Jin Park, Hyung Jung Kim
Journal of the Korean Society of Fractures 2000;13(4):709-712.
DOI: https://doi.org/10.12671/jksf.2000.13.4.709
Published online: June 21, 2016

Department of Orthopaedic Surgery, Yonsei University College of Medicine, Seoul, Korea.

os3410@yumc.yonsei.ac.kr

Copyright © The Korean Fracture Society

  • 26 Views
  • 0 Download
prev next
  • Metal failure (nail breakage) after locked intramedullary nailing results from delayed union or nonunion, which necessitates removal of nail and interlocking screws. Breakage of interlocking screw(s) can be associated with failure of the intramedullary nail. It usually breaks into two parts. Proximal part, which contains the screw head, can be removed by screwdriver without difficulties. Distal part can be removed from the far cortex or be left in place if it does not hinder further procedures. We experienced a case of segmental breakage of distal interlocking screw, which was associated with failure of the femoral nail and nonunion. Middle part of the broken screw obstructed the hollow of the nail and complicated the removal of the broken nail.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Segmental Breakage of Distal Interlocking Screw Complicating removal of broken nail: A Case Report
        J Korean Soc Fract. 2000;13(4):709-712.   Published online October 31, 2000
        Close
      • XML DownloadXML Download
      We recommend
      Segmental Breakage of Distal Interlocking Screw Complicating removal of broken nail: A Case Report
      Segmental Breakage of Distal Interlocking Screw Complicating removal of broken nail: A Case Report

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP