Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 12(4); 1999 > Article
Original Article
Radiologic Follow-up Results of Distraction After Treatment of Distal Radius Fractures using External Fixator
Jong Oh Kim, Dong Wook Kim, Young Do Koh, Jae Doo Yoo, Kyoung Soo Kim
Journal of the Korean Society of Fractures 1999;12(4):988-994.
DOI: https://doi.org/10.12671/jksf.1999.12.4.988
Published online: June 23, 2016

Department of Orthopaedic Surgery, College of Medicine, Ewha Womans University, Seoul, Korea.

Copyright © The Korean Fracture Society

  • 26 Views
  • 0 Download
prev next
  • External fixation for severe fractures of the distal radius is accepted treatment offering the potential advantages of controlled distraction, accurate positioning of fracture fragments, and avoidance of extensive open procedures. One of the limitation of external fixation for distal radius fractures is excessive distraction, which affect the outcome. This study was conducted to evaluate the changes of the distraction of the intercarpal and radiocarpal joint, developed after treatment of distal radius fractures with external fixator. Restrospective study was done for 28 paitents, who were evaluated by chart review, questionnaire, radiograph, and physical examination. The carpal height ratio, radial inclination, velar tilt, radial length were measured in the postoperative and follow-up radiographs. The carpal height ratio was used to quantify the distraction. Functional evaluation was performed with Demerit-Point system described by Garthland and Werley. Five fractures had an excellent results, 16 had a good results, 4 had a fair results, and 3 had poor results. After union, average radial inclination was 21.3 degree, average dorsal angulation was -0.5 degree, and radial shortening was 1mm. Increased carpal height ratio of the 9 cases did not decrease to less than 0.56 at one year after operation. The over-distraction of intercarpal and radiocarpal joint developed after external fixation of the distal radius fracture, did not have decreased in the one year follow-up radiographs after operation. The over- distraction should be avoided intraoperativly.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Radiologic Follow-up Results of Distraction After Treatment of Distal Radius Fractures using External Fixator
        J Korean Soc Fract. 1999;12(4):988-994.   Published online October 31, 1999
        Close
      • XML DownloadXML Download
      We recommend
      Related articles
      Radiologic Follow-up Results of Distraction After Treatment of Distal Radius Fractures using External Fixator
      Radiologic Follow-up Results of Distraction After Treatment of Distal Radius Fractures using External Fixator

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP