  • PURPOSE: To evaluate optimal placement of the Herbert/Whipple screw in scaphoid fracture. MATERIALS AND METHODS: Forty eight models molded from four cadaver scaphoids were used for this study. Using the Herbert/Whipple jig, the guide wire was placed distal to proximal into each scaphoid with twelve method which were four entry points and three target points. Guide wire placement was then evaluated with three planes in the proximal, middle, distal planes and distance from the nearest cortex. RESULTS: The most concentric position in the proximal plane was D5, in the middle plane C10. As distal entry point, the most concentric position in proximal plane was C. There were no statistical concentric, as middle, distal plane, and proximal entry point, CONCLUSION: The most ideal placement were D5 in proximal fractures of the scaphoid, C5 in distal fractures. In waist fractures of the scaphoid, there were relatively safe, except A0 and D0. The position of entry points was more important than that of target points for ideal screw placement.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Ideal Placement of the Herbert/Whipple Screw in Scaphoid Fracture: A Model Study
        J Korean Soc Fract. 2002;15(4):581-586.   Published online October 31, 2002
        Close
      • XML DownloadXML Download
      We recommend
      Ideal Placement of the Herbert/Whipple Screw in Scaphoid Fracture: A Model Study
      Ideal Placement of the Herbert/Whipple Screw in Scaphoid Fracture: A Model Study

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP