  • PURPOSE: The purpose of this study was to compare the clinical results of subtrochanteric fractures which were treated with compression hip screw, intramedullary nailing and Rowe plate. MATERIALS AND METHODS: From 1991 to 1999, 84 cases of subtrochanteric fractures were treated in Chonnam national university hospital. Among them, 25 cases were treated with compression hip screw, 18 cases with interlocking IM nailing and 32 cases with Rowe plate. Excluding pathologic fracture, there were 24 cases(group A), 16 cases(group B) and 30 cases(group C) of subtrochanteric fractures which were followed over 1 year. Mean follow up period was 18, 21, 24 months each. We compared the fracture pattern, operation time, operation method, additional fixation, bone union and complications among the groups. RESULTS: We devided subtrochanteric fracture into below class II and above class III based on Seinsheimer classification. The overall clinical results were 1 case below class II, 22 above III in group A, 12 below II, 6 above II in group B, and 4 below II, 26 above III in group C. The average operation time was 153 minutes in group A, 166 in group B, and 150 in group C. Additional wiring was performed in 15 cases in group A, 1 in group B and 6 in group C. Interfragmentary screw fixation was performed only in group A(12 cases). Bone graft was performed in 6 cases in group A, 6 cases in group B and 11 cases in group C. The complications were as follows; delayed union 1 case in group A, 2 cases in group B and 6 cases in group C.; Nonunion only 1 case in group B; varus deformity 4 cases in group B and 2 cases in group C; metal failure 1 case in group B and 1 case in group C. CONCLUSIONS: In treatment of subtrochanteric fractures, compression hip screw was applied to more communited fractures than intramedullary nail, but with additional fixation safe union and excellent clinical outcomes obtained. For intramedullary nailing, great care should be taken not to produce varus malalignment. In plate fixation, we should keep in mind the possibility of metal failure and varus malalignment. Weight bearing should be delayed.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  
    • Extra-capsular proximal femoral fractures: a cohort comparison of union and complication rates after ballistic versus blunt trauma
      Jordan Cook Serotte, Kevin Chen, Julia Nascimben, Jason Strelzow
      European Journal of Orthopaedic Surgery & Traumatology.2025;[Epub]     CrossRef
    • Factors Affecting Time to Bony Union of Femoral Subtrochanteric Fractures Treated with Intramedullary Devices
      Jung-Yoon Choi, Yerl-Bo Sung, Jin-Hee Yoo, Sung-Jae Chung
      Hip & Pelvis.2014; 26(2): 107.     CrossRef
    • Efficacy of Percutaneous Cerclage Wiring in Intramedullary Nailing of Subtrochanteric Femur Fracture - Technical Note -
      Ki-Chul Park, Hee-Soo Kim
      Journal of the Korean Fracture Society.2013; 26(3): 212.     CrossRef
    • The Treatment of Subtrochanteric Fracture with Cephallomedually Nail -Minimal Incision and Lowman Clamp Assisted Reduction-
      Jang Seok Choi, Do Hyun Moon, Young Tae Noh
      Journal of the Korean Fracture Society.2011; 24(4): 301.     CrossRef

    • Cite
      CITE
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Treatment of subtrochanteric fracture - Comparison of treatment efficacy according to internal fixation device -
      J Korean Soc Fract. 2001;14(2):189-199.   Published online April 30, 2001
      Close
    • XML DownloadXML Download
    We recommend
    Treatment of subtrochanteric fracture - Comparison of treatment efficacy according to internal fixation device -
    Treatment of subtrochanteric fracture - Comparison of treatment efficacy according to internal fixation device -

    J Korean Soc Fract : Journal of the Korean Society of Fractures
    Close layer
    TOP