Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 7(2); 1994 > Article
Original Article
The Radiographic Analysis of Unstable Intertrochanteric Fractures Treated with Compression Hip Screw
Chang-Dong HAN, Kang-Soo CHANG, Ick-Hwan YANG, Jun-Sub JABNG
Journal of the Korean Society of Fractures 1994;7(2):235-241.
DOI: https://doi.org/10.12671/jksf.1994.7.2.235
Published online: July 13, 2016

Department of Orthopedic Surgery, Yonsei University College of Medicine, Korea.

Copyright © The Korean Fracture Society

  • 34 Views
  • 0 Download
prev next
  • We have treated 30 cases of unstable intertrochanteric fractures of the femur with hip compression screw and side plate from Jan. 1990 to Dec. 1992. We compared the collapse amount of facture site between anatomic reduction and medial displacement(medialization), and analysed the site of lag screw in femoral head and rediographic result.
    1. The degree of fracture site collapse was measured as 3.83mm(mean) in anatomic reduction cases and 5.13mm(mean) in medial displacement cases.
    2. The lag screws position in femoral head was as followed 6 cases(20%) in cranial position, 16 cases(53%) in central position, 8 cases(27%) in caudal position on anteroposterior view ; 3 cases(10%) in anterior position, 15 cases(50%) in central position, 12 cases(40%) in posterior position on lateral view.
    3. The union rate was 100 percent. But the penetration of lag screw into the joint occured in three cases, in which the lag screw was located in cranial position on anteroposterior view.
    There was no difference in union rate and degree of fracture site collapse between anatomic reduction and medial displacement cases. But the best result was obtaned by central positioning of lag screw and firm internal fixation.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        The Radiographic Analysis of Unstable Intertrochanteric Fractures Treated with Compression Hip Screw
        J Korean Soc Fract. 1994;7(2):235-241.   Published online November 30, 1994
        Close
      • XML DownloadXML Download
      We recommend
      The Radiographic Analysis of Unstable Intertrochanteric Fractures Treated with Compression Hip Screw
      The Radiographic Analysis of Unstable Intertrochanteric Fractures Treated with Compression Hip Screw

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP