Skip Navigation
Skip to contents

J Korean Soc Fract : Journal of the Korean Society of Fractures

OPEN ACCESS

Articles

Page Path
HOME > > Volume 13(1); 2000 > Article
Original Article
Mechanical Properties of External Fixator according to Its Arrangement and Structure
Hong Jun Han, Byung Chang Lee, Yeung Jin Kim, Byung Soo Jin, Gun Hyee Lee
Journal of the Korean Society of Fractures 2000;13(1):38-45.
DOI: https://doi.org/10.12671/jksf.2000.13.1.38
Published online: June 23, 2016

Department of Orthopaedic Surgery, Wonkwang University Hospital, Iksan, Korea.

Department of Mechanical Engineering, Wonkwang University, Iksan, Korea.

hhj@wonnms.wonkwang.ac.kr

Copyright © The Korean Fracture Society

  • 49 Views
  • 0 Download
prev next
  • PURPOSE: To obtain the accurate knowledge of the fundamental mechanical properties of the external fixator affected by variations in arrangements and structures. We used newly developed external fixator, Anyfix, universal testing machine and plastic padding bone model which had similar structural properties to human tibia. The measured performance for seven different configurations of external fixators was its ability to control the motion of the bone fragment at the fracture site. Based on a unit of applied load, the corresponding displacement measured at the fracture site was used to described the stiffness of the fixation device for each load. Three stiffness moduli can be determined as axial stiffness, anterior posterior bending stiffness and lateral bending stiffness. RESULTS: In basic configuration, all three stiffnesses for unilateral two plane external fixator showed marked increase than those for unilateral one plane model. Axial compression stiffness and bending stiffness were increased when ring component were located far from the fracture site. In modified configuration, all three stiffnesses were increased when the number of pin was increased and small sized ring was used. CONCLUSION: The stiffness of the external fixator can be substantially increased by using unilateral two plane, locating the ring at far portion from the fracture site, using a small sized ring and increasing the number of pins.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Mechanical Properties of External Fixator according to Its Arrangement and Structure
        J Korean Soc Fract. 2000;13(1):38-45.   Published online January 31, 2000
        Close
      • XML DownloadXML Download
      We recommend
      Mechanical Properties of External Fixator according to Its Arrangement and Structure
      Mechanical Properties of External Fixator according to Its Arrangement and Structure

      J Korean Soc Fract : Journal of the Korean Society of Fractures
      Close layer
      TOP