Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Articles

Page Path
HOME > J Musculoskelet Trauma > Volume 18(1); 2005 > Article
Original Article
Fixation Failure of Unstable Intertrochanteric Fracture of the Femur Using Compression Hip Screw
Sang Won Park, Soon Hyuck Lee, Jong Ryoon Baek, Sung Jun Park, Jong Won Chung
Journal of the Korean Fracture Society 2005;18(1):1-5.
DOI: https://doi.org/10.12671/jkfs.2005.18.1.1
Published online: June 16, 2016

Department of Orthopadic Surgery, Korea University Hospital, Seoul, Korea.

kuosam@kumc.or.kr

Copyright © The Korean Fracture Society. All rights reserved

  • 98 Views
  • 0 Download
next
  • PURPOSE: To investigate the factors which influence on the fixation failure after the compression hip screw fixation for unstable intertrochanteric fractures. MATERIALS AND METHODS: Eighty-two patients of unstable intertrochanteric fracture of A2 and A3 type who had underwent operation with compression hip screw were evaluated at least 1 year follow-up in regard to the age, degree of osteoporosis, fracture type, diastasis of fragment, sliding of lag screw, position of lag screw and status of reduction. RESULTS: 73 patients out of 82 patients had the union and 9 patients showed fixation failure. The results of fixation failure were 6 cases of migration of lag screw and 3 cases of cut-out of lag screw. There were statistically significant correlations between fixation failure and A2.3 and A3 type. The fixation failure group showed increased medial migration of medial cortex of proximal and distal fragment, which is significantly correlated with fixation failure. There were little statistical significant correlations between age, degree of osteoporosis, status of reduction, position of lag screw, sliding of lag screw and fixation failure. CONCLUSION: Another alternative fixation method and technique have to be considered for unstable A2-3 or A3 type because compression hip screw fixation only is very insufficient with high failure rate.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Fixation Failure of Unstable Intertrochanteric Fracture of the Femur Using Compression Hip Screw
        J Korean Fract Soc. 2005;18(1):1-5.   Published online January 31, 2005
        Close
      • XML DownloadXML Download
      We recommend
      Fixation Failure of Unstable Intertrochanteric Fracture of the Femur Using Compression Hip Screw
      Fixation Failure of Unstable Intertrochanteric Fracture of the Femur Using Compression Hip Screw

      J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
      Close layer
      TOP