Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Search

Page Path
HOME > Search
2 "Ho Sung Jung"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Articles
Minimally Invasive Percutaneous Plate Stabilization of Proximal Tibial Fractures
Chang Wug Oh, Jong Keon Oh, In Ho Jeon, Hee Soo Kyung, Il Hyung Park, Joo Chul Ihn, Yeon Ki Woo, Ho Sung Jung
J Korean Fract Soc 2004;17(3):224-229.   Published online July 31, 2004
DOI: https://doi.org/10.12671/jkfs.2004.17.3.224
AbstractAbstract PDF
PURPOSE
Despite of various treatment methods, proximal tibial fractures are common injuries that may be associated with poor outcomes and high rates of complications. To improve this, percutaneous plating technique was performed in the proximal tibial fractures.
MATERIALS AND METHODS
Twenty-four proximal tibial fractures (AO 41A; 5, AO 41C; 12, AO 42; 7) were treated by percutaneous plating with either or both sides without bone graft. One was open fracture.
RESULTS
All fractures were healed. The average time for fracture healing was 16.5 weeks (range, 8~24 weeks). Complications included a 1cm shortened case and two mal-alignments; a 6 degree valgus case and 5 degree varus case. There was one case of superficial infection, which healed after plate removal. But, there was no deep infection. Results were evaluated by modified Rasmussen score system, all patients had excellent or good result.
CONCLUSION
Minimally invasive percutaneous plating technique can provide favorable results in the treatment of proximal tibial fractures.

Citations

Citations to this article as recorded by  
  • MINIMALLY INVASIVE OSTEOSYNTHESIS WITH PLATE OR NAIL FOR META-DIAPHYSEAL TIBIAL FRACTURES - WHAT IS BETTER?
    B. Makelov
    Trakia Journal of Sciences.2023; 21(4): 357.     CrossRef
  • Medial Minimally Invasive Percutaneous Plate Osteosynthesis in Proximal Tibial Comminuted Fractures
    Jae-Ang Sim, Kwang-Hui Kim, Yong-Seuk Lee, Sang-Jin Lee, Beom-Koo Lee
    Journal of the Korean Orthopaedic Association.2014; 49(4): 278.     CrossRef
  • Minimally Invasive Percutaneous Plate Stabilization Using a Medial Locking Plate for Proximal Tibial Fractures - Technical Note -
    Jae Ang Sim, Beom Koo Lee, Kwang Hui Kim, Yong Seuk Lee
    Journal of the Korean Fracture Society.2013; 26(4): 327.     CrossRef
  • Clinical Outcomes of Locking Compression Plate Fixation through Minimally Invasive Percutaneous Plate Osteosynthesis in the Treatment of Distal Tibia Fracture
    Jae-Sung Yoo, Hyun-Woo Park
    Journal of the Korean Fracture Society.2012; 25(2): 117.     CrossRef
  • Minimally Invasive Plate Osteosynthesis for Proximal Tibial Shaft Fracture
    Young-Soo Byun, Ki-Chul Park, Hyun-Jong Bong, Chang-Hoon Lee
    Journal of the Korean Fracture Society.2011; 24(1): 23.     CrossRef
  • Minimally Invasive Plate Osteosynthesis for the Upper Extremity Fracture Using a Lumbar Spreader - Surgical Technique -
    Gu-Hee Jung, Chyul-Hyun Cho, Jae-Do Kim
    Journal of the Korean Fracture Society.2011; 24(1): 83.     CrossRef
  • Management of Fractures of Distal Tibia by Minimally Invasive Plate Osteosynthesis through an Anterior Approach
    Gu-Hee Jung, Jae-Do Kim, Jae-Ho Jang, Sung-Keun Heo, Dong-won Lee
    Journal of the Korean Orthopaedic Association.2010; 45(6): 473.     CrossRef
  • The Comparison of Minimally Invasive Plate Osteosynthesis and Intramedullary Nailing in the Treatment of the Proximal and Distal Tibia Fracture
    Joon Soon Kang, Seung Rim Park, Sang Rim Kim, Yong Geun Park, Jae Ho Jung, Sung Wook Choi
    Journal of the Korean Fracture Society.2010; 23(2): 172.     CrossRef
  • Staged Minimally Invasive Plate Osteosynthesis of Proximal Tibial Fracture
    Joon-Woo Kim, Chang-Wug Oh, Jong-Keon Oh, Hee-Soo Kyung, Woo-Kie Min, Byung-Chul Park, Kyung-Hoon Kim, Hee-Joon Kim
    Journal of the Korean Fracture Society.2009; 22(1): 6.     CrossRef
  • Proximal Tibia Fracture: Plating
    Ki-Chul Park
    Journal of the Korean Fracture Society.2009; 22(3): 206.     CrossRef
  • 104 View
  • 0 Download
  • 10 Crossref
Close layer
Minimally Invasive Plate Osteosynthesis for Distal Femoral Fractures
Sung Jung Kim, Chang Wug Oh, In Ho Jeon, Hee Soo Kim, Byung Chul Park, Hee Soo Kyung, Joo Chul Ihn, Ho Sung Jung
J Korean Soc Fract 2003;16(4):474-481.   Published online October 31, 2003
DOI: https://doi.org/10.12671/jksf.2003.16.4.474
AbstractAbstract PDF
PURPOSE
We retrospectively reviewed the outcomes and advantages of minimal invasive plating osteosynthesis (MIPO) technique as a new treatment of distal femoral fractures.
MATERIALS AND METHODS
Sixteen supracondylar femoral fractures (15 patients) were treated by MIPO technique and evaluated radiologically and functionally after minimal 1 year follow-up (average; 22 months, range; 13~42 months). There were 9 women and 6 men with a mean age of 46 years old (range 35 to 64 years). Seven fractures were extended into knee joints (AO/OTA type C), and 9 were extraarticular (AO/OTA type A). Five cases were open fractures (type I; 2, type II; 3) according to the Gustilo-Anderson classification. After minimal lateral parapatellar incision and accurate reduction of intra-articular fractures, the supracondylar fractures were fixed by percuatneous plating method without exposure of fracture area. Neer scoring was used for functional evaluation of knee.
RESULT
At a mean of 17 weeks (range 14 to 22), most fractures united without secondary procedures. One case of nonunion had the procedure of bone graft, but there were no other complications including shortening over 1 cm, mal-alignment over 10 degrees, or deep infections. All the cases had good or excellent knee function, and the average range of knee motion was 120.6 degrees.
CONCLUSION
MIPO technique is a worthwhile method of managing distal femoral fractures with good unions and functional recovery.

Citations

Citations to this article as recorded by  
  • The Comparison of Minimally Invasive Percutaneous Plate Osteosynthesis versus Open Plate Fixation in the Treatment of in the Distal Femur Fracture
    Seong-Jun Ahn, Suk-Woong Kang, Bu-Hwan Kim, Moo-Ho Song, Seong-Ho Yoo, Kwan-Taek Oh
    Journal of the Korean Fracture Society.2013; 26(4): 314.     CrossRef
  • Treatment of Distal Femur Fracture with Minimally Invasive Locking Compression Plate Osteosynthesis
    Ki-Chul Park, Kyu-Sung Chung, Joon-Ki Moon
    Journal of the Korean Fracture Society.2012; 25(1): 13.     CrossRef
  • Axial Malalignment after Minimally Invasive Plate Osteosynthesis in Distal Femur Fractures with Metaphyseal Comminution
    Jae-Ho Jang, Gu-Hee Jung, Jae-Do Kim, Cheung-Kue Kim
    Journal of the Korean Orthopaedic Association.2011; 46(4): 326.     CrossRef
  • Surgical Treatment of AO Type C Distal Femoral Fractures Using Locking Compression Plate (LCP-DF, Synthes®)
    Kap-Jung Kim, Sang Ki Lee, Won-Sik Choy, Won-Cho Kwon, Do Hyun Lee
    Journal of the Korean Fracture Society.2010; 23(1): 20.     CrossRef
  • What is an Ideal Treatment?
    Chang-Wug Oh
    Journal of the Korean Fracture Society.2008; 21(4): 347.     CrossRef
  • 117 View
  • 0 Download
  • 5 Crossref
Close layer

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
Close layer
TOP