Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Articles

Page Path
HOME > J Musculoskelet Trauma > Volume 18(4); 2005 > Article
Original Article
Conformity of the LCP-DF (Locking Compression Plate-Distal Femur) in Korean Adult Femur: A Cadaver Study
Jong Keon Oh, Chang Wug Oh, Sun Hwa Park, Kwon Jae Roh, Chang Won Jeong
Journal of the Korean Fracture Society 2005;18(4):399-404.
DOI: https://doi.org/10.12671/jkfs.2005.18.4.399
Published online: June 16, 2016

Department of Orthopedic Surgery, Dongdaemun Hospital, Ewha Womans University, Seoul, Korea.

Department of Orthopedic Surgery, Kyungpook National University Hospital, 50, 2-Ga, SamDok-Dong, Chung-Gu, Daegu, 700-721, Korea.

Department of Anatomy, College of Medicine, Korea University, Anam-dong 5ga, Seongbuk-gu, 136-705, Seoul Korea.

jongkeon@ewha.ac.kr

Copyright © The Korean Fracture Society. All rights reserved

  • 67 Views
  • 0 Download
  • 5 Crossref
prev next
  • PURPOSE: To evaluate the conformity of the anatomically pre-shaped LCP-DF to the femurs of the Korean adult. MATERIALS AND METHODS: 67 adult femur obtained from the Korean adult cadaver were used. An eleven-hole LCP-DF was applied to the lateral surface of the distal femur according to the contour. Then the distance from the inner surface of the plate to the cortex was measured at the sites of mismatch. The angle between the distal most screw and the articular surface was measured. RESULTS: Mismatch was found at the level of proximal 4~5 holes of the plate with an average distance of 9.58 mm (0~18) at the tip of the plate. Otherwise, the overall conformity of the LCP-DF was excellent. The distal most screws are positioned such that the joint line is 3 degrees of valgus to this screw in average (range 0~18). CONCLUSION: It may be necessary to consider to bend the plate in case of mismatch at the tip especially for the plate longer than 9-hole plate. The angular relation between the distal most screw and the joint line can assist the judgement for the coronal plane alignment.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  
    • Comparison of Results of Minimally Invasive Plate Osteosynthesis according to Types of Locking Plate in Distal Femoral Fractures
      Oog Jin Shon, Moon Soo Kwon, Chul Hyun Park
      Journal of the Korean Fracture Society.2012; 25(4): 269.     CrossRef
    • Repeated Metal Breakage in a Femoral Shaft Fracture with Lateral Bowing - A Case Report -
      Dong Soo Kim, Yong Min Kim, Eui Sung Choi, Hyun Chul Shon, Kyoung Jin Park, Byung Ki Cho, Ji Kang Park, Hyun Cheol Lee, Kyung Ho Hong
      Journal of the Korean Fracture Society.2012; 25(2): 136.     CrossRef
    • Axial Malalignment after Minimally Invasive Plate Osteosynthesis in Distal Femur Fractures with Metaphyseal Comminution
      Jae-Ho Jang, Gu-Hee Jung, Jae-Do Kim, Cheung-Kue Kim
      Journal of the Korean Orthopaedic Association.2011; 46(4): 326.     CrossRef
    • Treatment of Distal Femoral Fractures Using Polyaxial Locking Plate
      Sang-Eun Park, Hyun-Taek Kang, Young-Yul Kim, Jae-Jung Jeong, Jung-U Lee, Weon-Yoo Kim
      Journal of the Korean Fracture Society.2011; 24(4): 321.     CrossRef
    • Pitfalls and Complications in the Application of the Locking Plate
      Jong-Keon Oh
      Journal of the Korean Fracture Society.2007; 20(4): 355.     CrossRef

    • Cite
      CITE
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Conformity of the LCP-DF (Locking Compression Plate-Distal Femur) in Korean Adult Femur: A Cadaver Study
      J Korean Fract Soc. 2005;18(4):399-404.   Published online October 31, 2005
      Close
    • XML DownloadXML Download
    We recommend
    Conformity of the LCP-DF (Locking Compression Plate-Distal Femur) in Korean Adult Femur: A Cadaver Study
    Conformity of the LCP-DF (Locking Compression Plate-Distal Femur) in Korean Adult Femur: A Cadaver Study

    J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
    Close layer
    TOP