Skip Navigation
Skip to contents

J Musculoskelet Trauma : Journal of Musculoskeletal Trauma

OPEN ACCESS

Articles

Page Path
HOME > J Musculoskelet Trauma > Volume 19(4); 2006 > Article
Original Article
Radiological Landmarks for the Assessment of the Alignment in the Use of the LCP-PLT (Locking Compression Plate-Proximal Lateral Tibia): An Anatomical and Radiological Study
Jong Keon Oh, Chang Wug Oh, Kwon Jae Roh, Hoon Sang Sohn
Journal of the Korean Fracture Society 2006;19(4):477-481.
DOI: https://doi.org/10.12671/jkfs.2006.19.4.477
Published online: June 16, 2016

Department of Orthopedic Surgery, Dongdaemun Hospital, Ewha Womans University College of Medicine, Seoul, Korea.

Department of Orthopedic Surgery, Kyungpook National University Hospital, Daegu, Korea.

jongkeon@ewha.ac.kr

Copyright © The Korean Fracture Society. All rights reserved

  • 84 Views
  • 0 Download
prev next
  • PURPOSE: To evaluate the conformity of the anatomically pre-shaped LCP-PT to the tibias of the Korean adult and to identify radiological guidelines to assist intraoperative assessment of correct alignment. MATERIALS AND METHODS: 30 adult femur obtained from the Korean adult cadaver were used. A nine or eleven-hole LCP-DF was applied to the lateral surface of the tibia according to the contour. Then the distance from the inner surface of the plate to the lateral condyle was measured at the sites of mismatch. The angle between the most proximal screw and the articular surface was measured with the image intensifier. RESULTS: The LCP-PT showed good conformity to the tibia in general. The distance from the inner surface of the plate to the lateral condyle was 3.5mm in average (range 0~9). The angle between the most proximal locking screw and the joint line was 1.16 degrees in average (range 0~7°). CONCLUSION: The LCP-PT showed good conformity to the tibia in general. Malposition of the most proximal screw which is not paralleling to the joint line may herald a coronal plane malalignment.

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Radiological Landmarks for the Assessment of the Alignment in the Use of the LCP-PLT (Locking Compression Plate-Proximal Lateral Tibia): An Anatomical and Radiological Study
        J Korean Fract Soc. 2006;19(4):477-481.   Published online October 31, 2006
        Close
      • XML DownloadXML Download
      We recommend
      Radiological Landmarks for the Assessment of the Alignment in the Use of the LCP-PLT (Locking Compression Plate-Proximal Lateral Tibia): An Anatomical and Radiological Study
      Radiological Landmarks for the Assessment of the Alignment in the Use of the LCP-PLT (Locking Compression Plate-Proximal Lateral Tibia): An Anatomical and Radiological Study

      J Musculoskelet Trauma : Journal of Musculoskeletal Trauma
      Close layer
      TOP